In Auto mode, to temporary override the current set temperature,

1. Press up or down button once, the set temperature starts flashing    

2. Press up or down button again to adjust the set temperature    
3. Press           or wait for 5 seconds to confirm the setting with “ Temporary ” shown on LCD    

 Now your thermostat will maintain the new set temperature until  the next program.To 

 cancel the override setting, press and hold button       for 5 seconds until “Temporary” 

Press button  M  to select Auto mode. In Auto mode, the LCD will display “AUTO” on the top left corner.
The thermostat executes the preprogrammed schedules in Auto mode.
To adjust these schedules, follow the easy steps below,

press  button   M     to select vacation mode        .

Vacation mode  will maintain a set temperature(default 10

°C) all the time.

 

Your thermostat has the ability to reset all settings to the factory defaults. If you are

certain you want to do this: In standby mode(when thermostat is turned off), press 

If thermostat is set in AF model, and set to show air temperature only, press and 

automatically revert back to air temperature in 5 seconds. 

hold the down button for 3 seconds, floor temperature will show and it will 

This product should be installed by

a qualified electrician.

Installation and Wiring

Dimensions

Wiring Diagram

86mm

m

m6

8

Rear View

45mm

13mm

27 mm

26 m

m

Side View

60mm

m

m6

8

86mm

4mm

m

m7

To lock the buttons, press and hold the up and down buttons for 3 seconds until you

see a lock icon appearing, to unlock, repeat the steps above.  

 

and hold button M and       for 5 seconds until “RES” is shown for 5 seconds on LCD.

This thermostat is fitted with a real time clock. It is essential that  the clock time and day 

are set accurately if you require your programmed events to start on time. Follow the   

Set the Time and Day 

Auto  Mode

Program your thermostat

Resetting factory defaults

Lock the buttons

View floor temperature

Temporary temperature override

Vacation mode 

Press the button      once

Use up or down button to change the time (Hold up or down button to change

Press button       again, the day of the week will flash  

Press button       again to accept and exit

Use up or down button to change the day of the week

  

Press and hold button        for 5 seconds until you see a day flashing. Use up or down button 

adjust the day (hold up or down button for 5 seconds to set all days).

 

 

 To erase program 2 and 3 for Saturday and Sunday,see below,

Note: It is faster to program the same schedule for the entire week and then to adjust the 

 

Press button         again and use up or down button to set the desired temperature to be 

 

 

Press button       to accept and exit. 

 

Press button       to bring up the program 1(       ).Use up or down button to set the start time

In step 1, select Saturday or Sunday.
In step 4, instead of using up or down button  , using button           will erase the time.(--:--).
In step 6, instead of using up or down button  , using button           will erase the time.(--:--).

 

 

and the time will flash 

Step 1.

Step 2.

Step 3.

Step 4.

Step 5.

 Press up or down button to change the set point and press      to accept and exit.  

Carefully separate the front half of the thermostat 

from the back plate by placing a small flat head

terminal driver into the slots on the bottom face of

the thermostat

1

1

2

3

4

5

6

7

8

9

10

Carefully unplug the ribbon connector

 which is plugged in to the front half of

the thermostat

2

Place the thermostat front half somewhere

safe. Terminate the thermostat as shown 

in the diagrams below

3

Screw the thermostat back

plate on to the back box

4

Re-connect the thermostat ribbon cable 

and clip the two halves  together

5

(default 07:00).(Hold up or down button to change by 15 minutes each time.)

Press button       to bring up the program 2(       ). Use up or down button to set the start time

(default 09:30). (Hold up or down button to change by 15 minutes each time.)

 

Press button       to bring up the program 3(       ). Use up or down button to set the start time

(default 16:30). (Hold up or down button to change by 15 minutes each time.)

 

 

Press button      to bring up the program 4(       ). Use up or down button to set the start time

(default 22:30). (Hold up or down button to change by 15 minutes each time.)

maintained for program 1.(default 22 

°C

Press button          again and use up or down button to set the desired temperature to be 

maintained for program 3.(default 22 

°C

 

Press button           again and use up or down button to set the desired temperature to be 

maintained for program 2.(default 16 

°C

 

Press button           again and use up or down button to set the desired temperature to be 