Monitoring Energy Consumption 

When requested by controller or gateway, the Mini Energy Switch will report immediate voltage, 
current,  power,  and  energy  consumption  (the  command  classes  which  support  this  function  is 
Meter  Command  Class).  When  set  unsolicited  report,  the  module  will  send  data  to  association 
group 1 at regular time. 
 

Parameter Number 

0x02 

Size 

1 BYTE 

Default value 

0x00 

Configuration value 

Bit 0: KWH Report 
Bit 1: Voltage Report 
Bit 2: Current Report 
Bit 3: Watt Report 
(Bit Set to 1: enable    0:disable) 

 
The interval time can be set as follows: 

Parameter Number 

0x03 

Size 

2 BYTE 

Default value 

0x0258 (10 minute) 

Configuration value 

0~65535 sec 

 

Setting & Activating Scene 

The  module  can  set  and  activate  255  scene  IDs  by  using  gateway  and  scene  controller.  The 
“SCENE_ACTUATOR_CONF_SET” in “COMMAND_CALSS_SCENE_ACTUATOR_CONF” is used to set 
scene,  and  “SCENE_ACTIVATION_SET”  in  “COMMAND_CLASS_SENE_ACTIVATION”  is  used  to 
activate scene. Please refer to instructions provided by controller manufacturer for details. 
 

Restoring Factory Settings 

The default configuration can be restored by: 

 

Sending commands through controller or gateway (the command classes which support this 
function is Configuration Command Class). The parameter are as follows: 
 

Parameter Number 

0xFF 

Size 

1 BYTE 

Default value 

N/A 

Configuration value 

0x55 

Set 0xFF as 0x55 will restore Factory Settings. 
 

 

Pressing and Holding the ON/OFF/PROGRAM button for 15s. 

Note

If the Factory Settings is restored successfully, INDICATION LED will blink quickly and then 

become slower.   
 
 

 