www.mcohome.com User Manual
MCOHome Technology Co., Ltd 2013
3
EXCLUDING the Mini Energy Switch from your network:
1.
Set the controller into EXCLUSION mode. Follow the instructions provided by the controller
manufacturer.
2.
Press the ON/OFF/PROGRAM button on the Mini Energy Switch, or toggle the external
switch/button 6 times in quick succession (within approx 2sec).
Note: If the exclusion is successful, the Mini Energy Switch INDICATION LED will blink slowly. If not,
INDICATION LED will be solid on or off depending on switch’s state.
Turning on/off the Mini Energy Switch
The Mini Energy Switch can be controlled by:
Toggling external switch/Button.
Pressing the ON/OFF/PROGRAM button on the Mini Energy Switch.
Sending commands through controller or gateway.
(
the command classes which support this
function are Basic Command Class, Binary Switch Command Class, and Scene Activation
Command Class
)
Changing External Control Mode
The external control mode can be configured by: (the default control mode of this module is
external switch)
Sending commands through controller or gateway (the command class which supports this
function is Configuration Command Class)
:
Pressing the ON/OFF/PROGRAM button 6 times in quick succession (within approx 2sec).
Setting Association Group
The module supports 2 association groups. The 1st group can support 5 association nodes. When
set unsolicited report, the 1st group will send data to its associated devices initiatively. See details
in
“
Monitoring Energy Consumption
”
The 2
nd
group is used for reporting devices’ state to the controller if any changes happen. This
group supports one node, which defaults to controller node.
The “ASSOCIATION_SET” in “COMMAND_CLASS_ASSOCIATION” command class is used to set
Grouping identifier and Node ID of association devices. Using “ASSOCIATION_GET” to get the
association device’s Node ID, and “ASSOCIATION_REMOVE” to remove the association device.
Parameter Number
0x01
Size
1 BYTE
Default value
0x00
Configuration value
0x00: Switch(
2 state switch mode
)
0x01: Button(
Momentary button mode
)
Command Classes
COMMAND_CLASS_ASSOCIATION_V1
Command Name
ASSOCIATION_SET
Grouping identifier
0x01 / 0x02
Node ID
Node ID that need to be included