Remote Control Output
When the remote control signal input, the icon of remote is blinking; when the detected
indoor temperature
≤
the set temperature for -2.5, electrical heating will be turned on, and the
icon
will be displayed on the screen; meanwhile, the Relout start output signals, when the
detected indoor temperature
≥
the set temperature, electrical heating will be turned off, and the
icon
will be disappeared, meanwhile, the Relout close turn off output signal. The setting
default temperature is 16.5
℃
(61
℉
) on the remote control mode.
Notes
: Remote signal control output has the highest priority.
Sensor Failure
When sensor failed to work, the icon EEE will display on the screen. The output will be closed.
Cumulative Time of the valve
In shutdown interface, long press
button, the cumulative time of the valve will be displayed
on the screen. The cumulative time will reset and restarted when press
and
buttons
simultaneously.
(
Unit
:
min
)
Temperature Unit Switching
In shutdown interface, long press
and
can switch the temperature unit settings.
Z-Wave Operation
Including & Excluding of Z-Wave network
In normal working interface, press & hold
to enter interface for inclusion or exclusion
of Z-Wave network. Before device included into network, “- - -” will display on the screen. Then
press
once, device will enter learning mode to get a node ID. If inclusion is success, a node
ID will display on the screen in a few seconds.
A node ID can always inform us whether the device is in the network or not.
Note: Follow the same steps to exclude the device from the network.
After inclusion, turn off the device and then turn it on. Now the device is ready to be operated
by controller/ gateway in Z-Wave network.