MCO Home MH4 Скачать руководство пользователя страница 6

 

                                                      www.mcohome.com                                        User Manual

 

MCOHome Technology Co., Ltd   

     

 

6

 

 

Floor Temperature Control Mode 

:  Floor  Temperature  Control, 

:  Room  Temperature  Control, 

:  Room 

Temperature Control with floor high temperature protection.

 

        When  the  icon

  displays  on  the  screen  indicates  the  system  is  in  Floor  Temperature 

Control Mode, and the icon 

will be displayed beside the temperature value

  it indicates the 

current detected temperature is the floor temperature. When the detected indoor temperature 

 

the  set  temperature  for  -1.5

℃,

electrical  heating  will  be  turned  on,  and  the  icon 

  will  be 

displayed on the screen; when the detected indoor temperature

  the set temperature

  electrical 

heating will be turned off, the icon 

  disappeared. 

 

 

Room Temperature Control Mode 

        When  the  icon 

  displays  on  the  screen  indicates  the  system  is  in  Room  Temperature 

Control Mode, when the icon 

  displays on the screen, it indicates the current temperature that 

displayed on the screen is the indoor temperature. When the detected indoor temperature 

  the 

set temperature for 2.5

, electrical heating will be turned on, and the icon 

  will be displayed 

on the screen; when the detected indoor temperature

  the set temperature, electrical heating will 

be turned off, and the icon 

  will be disappeared from the screen. 

 

 

Room Temperature Control, Floor High Temperature Limit Mode 

If the icon 

  displays on the screen, it indicates the system is in the Room Temperature 

Control  ,Floor  High  Temperature  Limit  Mode,    when  the  icon 

  displays  on  the  screen,  it 

indicates the current temperature that displayed on the screen is the indoor temperature. When the 
detected indoor temperature 

  the set temperature for-2.5

, electrical heating will be turned on, 

and  the  icon 

  will  be  displayed  on  the  screen;  when  the  detected  indoor  temperature 

  set 

temperature, electrical heating will be turned off, and the icon 

  will be disappeared. Press 

 

and 

  buttons simultaneously, the displayed temperature will switch to the floor temperature, 

and the icon 

  will display beside the temperature. When the temperature is higher than 

45℃

(113℉)

, the output will be closed, and then the icon 

  will be displayed on the screen to 

avoid overheating the floor. When the floor temperature reduced to 

40℃(104℉)

, electrical heating 

will be turned on again, and the icon 

  will be disappeared. 

Содержание MH4

Страница 1: ...floor temperature Floor overheating protection GFCI leakage protection level 5mA Multi working modes to meet various user needs Time Period Schedule Mode Comfort Mode Energy saving Mode Vacation Mode...

Страница 2: ...be installed indoor a place with around 41 2 to 5 feet height above the floor where represents the average room temperature It should be away from direct sunlight any cover or any heat source to avoi...

Страница 3: ...be displayed on the screen OFF In normal working interface slide down the ON OFF button to turn it off It will display OFF on the screen and all outputs will be closed GFCI Test Enter into GFCI test...

Страница 4: ...rking interface directly and the values will be saved Working Mode Setting Icon displays on the screen indicates it is in Time Period Mode Icon displays on the screen indicates it is in Manual Mode Ic...

Страница 5: ...interface long press button to enter into the Time Period settings interface First the HOUR of the first period is blinking The blinking item is the adaptable item press or button to change the value...

Страница 6: ...heating will be turned on and the icon will be displayed on the screen when the detected indoor temperature the set temperature electrical heating will be turned off and the icon will be disappeared...

Страница 7: ...Time of the valve In shutdown interface long press button the cumulative time of the valve will be displayed on the screen The cumulative time will reset and restarted when press and buttons simultan...

Страница 8: ...TAT_SETPOINT COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_OPERATING_STAT E COMMAND_CLASS_TIME COMMAND_CLASS_TIME_PARAMETERS Note Basic CC is used to control energy saving mode and comfort mo...

Страница 9: ...operate the equipment FCC Interference Statement Part 15 105 b USA only This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC R...

Страница 10: ...16 P3 Temperature Backlash Value 2 4 0 5 10 1 18 P4 Key Volume Level 3 OF 1 9 OF OFF 1 9 Length of the Key Volume P5 Backlight Brightness NO NO OF NO Always on OF Energy Saving of Backlight P6 Control...

Страница 11: ...e 1 year Limited Warranty MCOHome warrants this product to be free from defects in material and workmanship under normal and proper use for one year from purchase date of the original purchaser MCOHom...

Отзывы: