63
4.5
Built-in Integrity Test (BIIT)
With a Built in Integrity Test (BIIT) function, the Smartfind M10 is constantly
monitoring and testing the integrity of the AIS transponder. Should an
abnormal condition be detected within the device, the Error LED will alert
with a flashing red light. The following conditions will cause the Error LED
to flash red
Antenna VSWR exceeding the maximum allowed level
MMSI not set
Background noise level exceeds allowable threshold (-77dBm)
GPS is unable to gain lock (3D fixed) after 30 minutes of losing GPS
signal
Low input power (< 8.6 V DC) (Error LED flash)