Page 27
9.3
Mounting instruction plate
The EPIRB is supplied with a rigid plate giving visual instructions on how to operate
the EPIRB in an emergency. Mount this next to your EPIRB as explained in section
8.2.1.
9.4
Marking Hydrostatic Release Unit (HRU) expiry
If you are installing a float-free EPIRB you
must
now mark the HRU expiry date. The
HRU has a 2 year in-service life which starts as soon as it gets exposure to a marine
environment. Hence the 2 years starts at installation and it is left to the customer to
mark this date during installation. A date 2 years into the future should be marked on
the HRU body and copied onto the label on the side of the enclosure. The HRU is
marked by cutting out the corresponding dates on its label, as shown on the separate
leaflet.
The enclosure should be marked using the alpha-numeric stickers provided, then
covering them with the clear adhesive label provided (but see 9.5 first). The preferred
date format is month and year, for example : JUN 2006.
Содержание SMARTFIND E5
Страница 1: ...SMARTFIND E5 G5 USER MANUAL mcmurdo mcmurdo mcmurdo mcmurdo ...
Страница 12: ...Page 7 Test button Strobe Red LED Green LED Activation switch Lanyard Sea switch Antenna ...
Страница 23: ...Page 18 Align slot with lug Locate end of antenna in slot Fit R clip ...
Страница 25: ...Page 20 Cover correctly fitted to base ...
Страница 42: ...Page 37 12 1 Declarations of Conformity ...
Страница 43: ...Page 38 ...
Страница 44: ...Page 39 ...
Страница 45: ...Page 40 ...
Страница 52: ...82 810 001 Issue 4 ...