4. FAULT FINDING
Due to the nature of the SART fault finding is limited. The steps shown below should be sufficient
to trace the fault to a major sub-assembly, which can then be replaced.
The sequence given below requires that each part is completed satisfactorily before proceeding
to the next part. It is, for example, assumed that any faults found at a particular stage are
remedied before continuing.
The following table is applicable to all versions of SART.
Fault
Cause
Action
Dead battery
Check battery volts
Displaced magnet
Check switch ring
Red LED never on
Faulty PCB
Replace PCB
SART in active mode
Remove input signal
No standby mode indication
Stuck in active mode
Replace PCB
No active mode indication
when SART triggered
Faulty PCB
Replace PCB
LED indicates active mode
But beeper does not sound
Faulty PCB
Replace PCB
Drift on PCB
Retune PCB
Frequency limits wrong
Faulty PCB
Replace PCB