SART tester features
The SART tester displays the results of the tests in three ways:
1. During and after the test, it displays the response as a graph of amplitude against frequency
– the ‘spectrum analyser’ display. The position of the tester should be adjusted to produce
the optimum response – it is desirable to receive the greatest possible strength of signal, but
not to saturate the 5420 receiver.
Spectrum analyser display
2. Once the test is complete, pressing F3 on the tester displays the frequency response of the
SART against time, and so shows a series of frequency sweeps. A magnified view (press F1)
is shown – note that the SART being displayed sweeps down from 9.5 GHz to 9.2 GHz. Note
the exact limits of the frequency sweep – 9.53 and 9.16 GHz – are displayed on this and the
next screen.
Sweep frequency display
3. Pressing F3 again displays the summary results with the PASS/WARN/FAIL classification.
Summary results