The MCLK12 Analog Clock is designed to be placed 

upright on a table or shelf, standing on its feet. It may 

also be wall mounted.

The clock produces very little heat of its own. 

However, it is advisable not to install the MCLK12 

directly above a heat generating device. Cool opera-

tion ensures the longest possible operating life for any 

electronic instrument.

Wall Mounting

The MCLK12 is supplied with two Wall Anchors for 

mounting the clock on a wall. The Wall Anchors will 

accommodate wall thickness ranging from 1/8 inch 

(0.318 cm) to 5/8 inch (1.59 cm) thick (typical residen

-

tial drywall construction). Refer to figure 2. Addi

-

tional wall fasteners may be needed when the wall 

thickness is greater then 5/8 of an inch or with other 

types of wall construction. It is recommended that the 

Professionals at your McIntosh Dealer, who are skilled 

in all aspects of installation and operation, install the 

MCLK12 Analog Clock and any associated audio/

video equipment.

1. Use the supplied MCLK12 Mounting Template 

sheet (drawn actual size) to determine the clock’s 

location on the wall. Refer to figure 1.

2. Temporarily tape the Mounting Template to the 

wall in the desired location.

3. Before performing step 4, make certain there is 

no plumbing, electrical wires, electronic cables or 

any heating/cooling duct 

work located in the wall 

behind where the clock 

will be mounted.

4. Using a drill equipped 

with a 3/8 inch (9.5 mm)

drill bit, drill two holes 

into the drywall as indicated on the Mounting 

Template. Refer to figures 1 and 3.

5. Remove the Mounting Template from the wall.

6. Locate the two supplied Wall Anchors and insert 

them into the just drilled openings in the wall. 

Refer to figures 2 and 4.

7. Using a suitable tool, 

lightly tap the Wall 

Anchors until the anti-

rotation tabs are into the drywall.

8. Using a suitable tool, 

rotate the screw head 

clockwise of the Wall 

Anchors until it starts to 

tighten up. It will take 

many turns. Refer to 

figures 5, 6 and 7.

9. Now rotate the screw of 

the Wall Anchor coun-

terclockwise about 6 and 

one half turns.

10. Try placing the MCLK12 

on the wall by lining up 

the rear panel openings of 

the clock with the screw 

heads of the Wall Anchors. If necessary adjust the 

Wall Anchor screws.

11. Proceed to the MCLK12 Rear Panel Connections 

on page 8. 

Dimensions and Installation

Installation

Center Line

Distance between mounting hole centers, 12” (30.48cm)

MCLK12 Front and Rear Panels shown actual size

+

+

8-3/4”

22.23cm

2-

1/16”

5.24cm

1-

3/4”

4.45cm

Center Line

1-

3/4”

4.45cm

2-

13/16”

7.14cm

2-

9/16

6.51cm

Rear Panel 

Mounting 

Opening

Rear Panel 

Mounting 

Opening

Figure 1

Figure 2

Dry

Wall

Drill

Bit

Figure 3

Dry

Wall

Wall

Anchor

Anti-Rotate

Tabs

Figure 4

Figure 5

Figure 6

Figure 7

Содержание MCLK12

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com MCLK12 Analog Clock Owner s Manual...

Страница 2: ...d for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularl...

Страница 3: ...of having to reset the cor rect time when AC Power is restored The MCLK12 may be supplied with a battery depending on the country where the MCLK12 is purchased When pur chasing a battery for use in t...

Страница 4: ...in need of repair you can return it to your Dealer You can also return it to the McIntosh Laboratory Service Department For assistance on factory repair return procedure contact the McIntosh Service D...

Страница 5: ...s and Hour Meters on the MCLK12 display the current time and are illuminated with extra long life Light Emitting Diodes LEDs Power Control The Power Control Input and Output connections provides conve...

Страница 6: ...ing the best location for your MCLK12 BACKUP BATTERY Front View of the MCLK12 Rear View of the MCLK12 Side View of the MCLK12 17 1 2 44 45cm 8 7 8 22 54cm 16 15 16 43 02cm 7 5 32 18 18cm 7 5 32 18 18c...

Страница 7: ...es electronic cables or any heating cooling duct work located in the wall behind where the clock will be mounted 4 Using a drill equipped with a 3 8 inch 9 5 mm drill bit drill two holes into the dryw...

Страница 8: ...efer to information on the back panel of your MCLK12 to determine the correct volt age for your unit POWER CONTROL INput receives a turn on signal from a Preamplifier or A V Control Center Removable c...

Страница 9: ...ystem may vary from this however the actual components would be connected in a similar manner For additional information refer to Connector and Cable Information on page 5 Power Control Connections 1...

Страница 10: ...ours and Minutes Meter indicates the current Hour Front Panel Displays and Controls Meter indicates the current Minute METER LIGHTS switches On Off illumination of the Meters Hours and Minutes also sw...

Страница 11: ...rrent time Front Panel Illumination When the MCLK12 is connected to a McIntosh Pre amplifier A V Control Center Integrated Amplifier or A V Receiver via the Power Control Connection the Front Panel Il...

Страница 12: ...12...

Страница 13: ...13 Photos...

Страница 14: ...ower Requirements 100V 50 60Hz at 2 0 Watts 110V 50 60Hz at 2 0 Watts 120V 50 60Hz at 2 0 Watts 220V 50 60Hz at 2 0 Watts 230V 50 60Hz at 2 0 Watts 240V 50 60Hz at 2 0 Watts Note Refer to the rear pan...

Страница 15: ...ng carton and interior parts only if they are all in good serviceable condition If a shipping carton or any of the interior part s are needed please call or write Customer Service Depart ment of McInt...

Страница 16: ...cts is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcin...

Отзывы: