McIntosh MCLK12 Скачать руководство пользователя страница 11

11

Setting the Time

The internal time keeping circuitry of MCLK12 is 

always active when the clock is connected to a live 

AC Outlet. The correct time needs to be manually set 

when the clock is conected for the first time. To set the 

current time perform the following:

1. Press and hold in the TIME ADJUST Control 

until only the Meter indicating 

HOURS is illuminated. Refer to 

figures 10 and 11.

2. Rotate the TIME ADJUST Control 

clockwise or counterclockwise to 

set the current Hour on the Meter.

3. Press in the TIME ADJUST 

Control once and the Meter indicat-

ing MINUTES will now be illuminated. Refer to 

figures 10 and 12.

4. Rotate 

the TIME 

ADJUST 

Control 

clockwise 

or counter-

clockwise 

to set the 

current 

Minute on 

the Meter.

5. Press in 

the TIME 

ADJUST 

Control 

once and both Meters will now be illuminated 

displaying the current time.

Front Panel Illumination

When the MCLK12 is connected to a McIntosh Pre-

amplifier, A/V Control Center, Integrated Amplifier 

or A/V Receiver via the Power Control Connection, 

the Front Panel Illumination of the clock will go On/

Off with the McIntosh Component.

The clock will continue to display the current time 

even when the Front Panel Illumination is Off. If the 

McIntosh Component offers remote control of meter 

illumination via the Power Control Connection the il-

lumination of the Meters on the clock will also go On/

Off.

The MCLK12 Front Panel METER LIGHTS 

Control also allows control of Meter and Front Panel 

Nomenclature Illumination. To select Meter and No-

menclature Illumination perform the following steps:

1. Rotate the METERS LIGHTS 

Control to switch the Meter illumi-

nation On/Off. Refer to figures 11, 

12 and 13.

2. Press the METERS LIGHTS Con-

trol to switch On/Off illumination 

of the Meter and Nomenclature.

How to Operate the Clock

Figure 10

Figure 11

Figure 12

Figure 13

How to Operate the Clock

Содержание MCLK12

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com MCLK12 Analog Clock Owner s Manual...

Страница 2: ...d for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularl...

Страница 3: ...of having to reset the cor rect time when AC Power is restored The MCLK12 may be supplied with a battery depending on the country where the MCLK12 is purchased When pur chasing a battery for use in t...

Страница 4: ...in need of repair you can return it to your Dealer You can also return it to the McIntosh Laboratory Service Department For assistance on factory repair return procedure contact the McIntosh Service D...

Страница 5: ...s and Hour Meters on the MCLK12 display the current time and are illuminated with extra long life Light Emitting Diodes LEDs Power Control The Power Control Input and Output connections provides conve...

Страница 6: ...ing the best location for your MCLK12 BACKUP BATTERY Front View of the MCLK12 Rear View of the MCLK12 Side View of the MCLK12 17 1 2 44 45cm 8 7 8 22 54cm 16 15 16 43 02cm 7 5 32 18 18cm 7 5 32 18 18c...

Страница 7: ...es electronic cables or any heating cooling duct work located in the wall behind where the clock will be mounted 4 Using a drill equipped with a 3 8 inch 9 5 mm drill bit drill two holes into the dryw...

Страница 8: ...efer to information on the back panel of your MCLK12 to determine the correct volt age for your unit POWER CONTROL INput receives a turn on signal from a Preamplifier or A V Control Center Removable c...

Страница 9: ...ystem may vary from this however the actual components would be connected in a similar manner For additional information refer to Connector and Cable Information on page 5 Power Control Connections 1...

Страница 10: ...ours and Minutes Meter indicates the current Hour Front Panel Displays and Controls Meter indicates the current Minute METER LIGHTS switches On Off illumination of the Meters Hours and Minutes also sw...

Страница 11: ...rrent time Front Panel Illumination When the MCLK12 is connected to a McIntosh Pre amplifier A V Control Center Integrated Amplifier or A V Receiver via the Power Control Connection the Front Panel Il...

Страница 12: ...12...

Страница 13: ...13 Photos...

Страница 14: ...ower Requirements 100V 50 60Hz at 2 0 Watts 110V 50 60Hz at 2 0 Watts 120V 50 60Hz at 2 0 Watts 220V 50 60Hz at 2 0 Watts 230V 50 60Hz at 2 0 Watts 240V 50 60Hz at 2 0 Watts Note Refer to the rear pan...

Страница 15: ...ng carton and interior parts only if they are all in good serviceable condition If a shipping carton or any of the interior part s are needed please call or write Customer Service Depart ment of McInt...

Страница 16: ...cts is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcin...

Отзывы: