background image

3

17. Do not defeat the safety purpose of the polarized or

grounding-type plug.

A polarized plug has two blades with one wider

than the other. A grounding type plug has two

blades and a third grounding prong. The wide

blade or the third prong are provided for your

safety. If the provided plug does not fit into your

outlet, consult an electrician for replacement of the

obsolete outlet.

18. Do not overload wall outlets, extension cords or inte-

gral convenience receptacles as this can result in a risk

of fire or electric shock.

19. To completely disconnect this equipment from the AC

Mains, disconnect the power supply cord plug from the

AC receptacle.

Care of Equipment:

20. Clean only with a dry cloth.

21. Do not permit objects or liquids of any kind to be

pushed, spilled and/or fall into the equipment through

enclosure openings.

22. Unplug the power cord from the AC power outlet

when left unused for a long period of time.

Repair of Equipment:

23. Refer all servicing to qualified service personnel. Ser-

vicing is required when the equipment has been dam-

aged in any way, such as power-supply cord or plug is

damaged, liquid has been spilled or objects have fallen

into the equipment, the equipment has been exposed to

rain or moisture, does not operate normally, or has

been dropped.

24. Do not attempt to service beyond that described in the

operating instructions. All other service should be re-

ferred to qualified service personnel.

25. When replacement parts are required, be sure the ser-

vice technician has used replacement parts specified by

McIntosh or have the same characteristics as the origi-

nal part. Unauthorized substitutions may result in fire,

electric shock, or other hazards.

26. Upon completion of any service or repairs to this prod-

uct, ask the service technician to perform safety checks

to determine that the product is in proper operating

condition.

Customer Service

Technical Assistance

Please Take A Moment

Thank You

Copyright 2001 

ã

 by McIntosh Laboratory, Inc.

The serial number, purchase date and McIntosh dealer

name are important to you for possible insurance claim or

future service. The spaces below have been provided for

you to record that information:

Your decision to own this McIntosh MC2102 Power Am-

plifier ranks you at the very top among discriminating mu-

sic listeners. You now have “The Best.” The McIntosh

dedication to “Quality,” is assurance that you will receive

many years of musical enjoyment from this unit.

Please take a short time to read the information in this

manual. We want you to be as familiar as possible with all

the features and functions of your new McIntosh.

Serial Number:
Purchase Date:
Dealer Name:

If it is determined that your McIntosh product is in need of

repair, you can return it to your dealer. You can also return

it to the McIntosh Laboratory Service Department. For as-

sistance on factory repair return procedure, contact the

McIntosh Service Department at:

McIntosh Laboratory, Inc.

2 Chambers Street

Binghamton, New York 13903

Phone: 607-723-3515

Fax: 607-723-1917

If at any time you have questions about your McIntosh

product, contact your McIntosh dealer who is familiar with

your McIntosh equipment and any other brands that may

be part of your system. If you or your dealer wish addi-

tional help concerning a suspected problem, you can re-

ceive technical assistance for all McIntosh products at:

McIntosh Laboratory, Inc.

2 Chambers Street

Binghamton, New York 13903

Phone: 607-723-1545

Fax: 607-723-3636

Содержание MC2102

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 FAX 607 724 0549 Owner s Manual MC2102 MC2102 Power Amplifier...

Страница 2: ...ions 11 Do not install near any heat sources such as radiators heat registers stoves or other equipment including amplifiers that produce heat 12 Do not use this equipment near water 13 Do not expose...

Страница 3: ...utions may result in fire electric shock or other hazards 26 Upon completion of any service or repairs to this prod uct ask the service technician to perform safety checks to determine that the produc...

Страница 4: ...size be used so that there will be minimum power loss The size is specified in Gauge Numbers or AWG American Wire Gauge The smaller the Gauge number the larger the wire size Connection Terminals will...

Страница 5: ...for mation on page 8 pertaining to installing the MC2102 into cabinets MC2102 Dimensions 17 3 4 45 09cm 8 7 8 22 54cm Front View of the MC2102 Rear View of the MC2102 Side View of the MC2102 10 1 8 25...

Страница 6: ...longer dimension Refer to figure 2 4 Remove the first layer of foam to expose the Tubes Refer to figure 3 5 Carefully remove the Tubes from the remaining pieces of foam and temporarily place them in...

Страница 7: ...s Caution To prevent electrical shock make sure that the MC2102 Tube Cover is installed before connecting the AC Power Cord Before operating the MC2102 locate the previously re moved Tube Cover and pe...

Страница 8: ...binet a quiet running ven tilation fan can be a definite asset in maintaining the coolest possible operating temperature A custom cabinet instal lation should provide the following minimum spacing dim...

Страница 9: ...rol center audio outputs POWER CONTROL IN receives turn On Off signals from a McIntosh component and the POWER CONTROL OUT sends that turn On Off signal to the next McIntosh component MODE switch sele...

Страница 10: ...hten the top portion of the terminal post to secure the banana plug in place Note The use of Banana Plugs is for use in the United States and Canada only 4 Locate the Terminal Connec tion Cover and pa...

Страница 11: ...11 How to Connect for Stereo To AC Outlet McIntosh C200C Controller McIntosh C200P Preamplifier Right Loudspeaker 4 ohm Left Loudspeaker 4 ohm...

Страница 12: ...e in the United States and Canada only 4 Connect the prepared four inch 10 16 cm Jumper Cable be tween the two COM Output ter minals and the ten inch 25 4 cm Jumper Cable between the appro priate Impe...

Страница 13: ...lel Jumper Cables 0RQR 3DUDOOHO RRNXS RQQHFWLRQV 6SHDNHU PSHGDQFH 6SHDNHU 1HJDWLYH RQQHFWLRQ 6SHDNHU 3RVLWLYH RQQHFWLRQ RKP HIW DQG 5LJKW RP RQQHFWLRQ HIW DQG 5LJKW 2XWSXW RKP RQQHFWLRQ RKP HIW DQG 5L...

Страница 14: ...rminal post to secure the ba nana plug in place Note The use of Banana Plugs is for use in the United States and Canada only 4 Locate the Terminal Connection Cover and pass the Loudspeaker Hookup Cabl...

Страница 15: ...o Connect for Mono Bridge 0RQR ULGJH RRNXS RQQHFWLRQV 6SHDNHU PSHGDQFH 6SHDNHU 1HJDWLYH RQQHFWLRQ 6SHDNHU 3RVLWLYH RQQHFWLRQ RKP HIW 2XWSXW RKP RQQHFWLRQ 5LJKW 2XWSXW RKP RQQHFWLRQ RKP HIW 2XWSXW RKP...

Страница 16: ...Output of the amplifier METER Switch selects the display modes of the Power Output Meters POWER Switch Turns AC Power Off Remote or On Remote On Indicator lights when the amplifier is in the Remote T...

Страница 17: ...It is elec tronically held to this power level until a higher power peak passes through the amplifier The meter pointer will then rise to the newer higher indication If no further power peaks are rea...

Страница 18: ...o Noise Ratio 100dB Intermodulation Distortion Maximum Intermodulation Distortion if instanta neous peak output does not exceed twice the rated output for any combination of frequencies from 20Hz to 2...

Страница 19: ...Skid This will ensure the proper equipment location in the Inner Carton Failure to do this will result in shipping dam age Use the original shipping carton and interior parts only if they are all in...

Страница 20: ...McIntosh Part No 040742 McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903...

Отзывы: