background image

3

A polarized plug has two blades with one wider

than the other. A grounding type plug has two

blades and a third grounding prong. The wide

blade or the third prong are provided for your

safety. If the provided plug does not fit into your

outlet, consult an electrician for replacement of the

obsolete outlet.

18. Do not overload wall outlets, extension cords or inte-

gral convenience receptacles as this can result in a risk

of fire or electric shock.

19. To completely disconnect this equipment from the AC

Mains, disconnect the power supply cord plug from the

AC receptacle.

Care of Equipment:

20. Clean only with a dry cloth.

21. Do not permit objects or liquids of any kind to be

pushed, spilled and/or fall into the equipment through

enclosure openings.

22. Unplug the power cord from the AC power outlet

when left unused for a long period of time.

Repair of Equipment:

23. Refer all servicing to qualified service personnel. Ser-

vicing is required when the equipment has been dam-

aged in any way, such as power-supply cord or plug is

damaged, liquid has been spilled or objects have fallen

into the equipment, the equipment has been exposed to

rain or moisture, does not operate normally, or has

been dropped.

24. Do not attempt to service beyond that described in the

operating instructions. All other service should be re-

ferred to qualified service personnel.

25. When replacement parts are required, be sure the ser-

vice technician has used replacement parts specified by

McIntosh or have the same characteristics as the origi-

nal part. Unauthorized substitutions may result in fire,

electric shock, or other hazards.

26. Upon completion of any service or repairs to this prod-

uct, ask the service technician to perform safety checks

to determine that the product is in proper operating

condition.

Customer Service

Technical Assistance

Please Take A Moment

Thank You

Copyright 2001 

ã

 by McIntosh Laboratory, Inc.

The serial number, purchase date and McIntosh dealer

name are important to you for possible insurance claim or

future service. The spaces below have been provided for

you to record that information:

Your decision to own this McIntosh MC126 Power Ampli-

fier ranks you at the very top among discriminating music

listeners. You now have “The Best.” The McIntosh dedica-

tion to “Quality,” is assurance that you will receive many

years of musical enjoyment from this unit.

Please take a short time to read the information in this

manual. We want you to be as familiar as possible with all

the features and functions of your new McIntosh.

Serial Number:
Purchase Date:
Dealer Name:

If it is determined that your McIntosh product is in need of

repair, you can return it to your dealer. You can also return

it to the McIntosh Laboratory Service Department. For as-

sistance on factory repair return procedure, contact the

McIntosh Service Department at:

McIntosh Laboratory, Inc.

2 Chambers Street

Binghamton, New York 13903

Phone: 607-723-3515

Fax: 607-723-1917

If at any time you have questions about your McIntosh

product, contact your McIntosh dealer who is familiar with

your McIntosh equipment and any other brands that may

be part of your system. If you or your dealer wish addi-

tional help concerning a suspected problem, you can re-

ceive technical assistance for all McIntosh products at:

McIntosh Laboratory, Inc.

2 Chambers Street

Binghamton, New York 13903

Phone: 607-723-1545

Fax: 607-723-3636

Содержание MC126

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 FAX 607 724 0549 Owner s Manual MC126 MC126 Power Amplifier...

Страница 2: ...tacle or other outlet unless the blades can be fully in serted to prevent blade exposure Attention pour pevenir les chocs elecriques pas utiliser cette fiche polarisee avec un prolongateur une prise d...

Страница 3: ...ock or other hazards 26 Upon completion of any service or repairs to this prod uct ask the service technician to perform safety checks to determine that the product is in proper operating condition Cu...

Страница 4: ...ilable from the McIntosh Parts Department Power Control Cable Part No 170 202 Six foot 2 conductor shielded with two 1 8 inch stereo mini phone plugs 2 For additional connection information refer to t...

Страница 5: ...ion on the next page pertaining to installing the MC126 into cabinets Dimensions 17 1 2 44 45cm 6 5 16 16 03cm 7 5 8 19 37cm 18 1 2 46 99cm 3 16 0 48cm 13 1 4 33 66cm 17 43 18cm Front View of the MC12...

Страница 6: ...onents are installed in a single cabinet a quiet run ning ventilation fan can be a definite as set in maintaining all the system com ponents at the coolest possible op erating temperature A custom cab...

Страница 7: ...the POWER CONTROL OUT sends that turn On Off signal to the next McIntosh component Loudspeaker OUPUT Connections for Stereo and Mono Bridge Modes of Operation for each pair of channels Main Fuse hold...

Страница 8: ...tor Spade lug or prepared wire connection Insert the spade lug connector or prepared section of the cable end into the terminal side access hole and tighten the terminal cap until the cable is firmly...

Страница 9: ...he MC126 for Six Channels Right Front Loudspeaker Left Front Loudspeaker Center Front Loudspeaker Right Surround Loudspeaker Left Surround Loudspeaker Back Surround Loudspeaker McIntosh A V Control Ce...

Страница 10: ...ector or prepared section of the cable end into the terminal side access hole and tighten the termi nal cap until the cable is firmly clamped into the terminal so the wires cannot slip out Refer to fi...

Страница 11: ...11 How to Connect the MC126 for Three Channels To AC Outlet Right Front Loudspeaker 8 ohm Center Front Loudspeaker 8 ohm Left Front Loudspeaker 8 ohm McIntosh A V Control Center...

Страница 12: ...nd or RIGHT SURRound Amplifier Channel POWER GUARD Circuit activates POWER Switch Turns AC power On Off Remote On Indicator lights when the amplifier is in the Remote Turn On Mode POWER GUARD LEDs lig...

Страница 13: ...y is required for other applications set the controls as desired Refer to figure 10 Mode Switch The MODE Switch allows a pair of MC126 channels to be used in two different operating configura tions Re...

Страница 14: ...rated output Intermodulation Distortion Maximum Intermodulation Distortion if instanta neous peak output per channel does not exceed twice the rated output for any combination of fre quencies from 20H...

Страница 15: ...g damage Use the original shipping carton and interior parts only if they are all in good serviceable condition If a shipping carton or any of the interior part s are needed please call or write Custo...

Страница 16: ...McIntosh Part No 040650 McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903...