IMPORTANT SAFETY

INSTRUCTIONS!

PLEASE READ THEM BEFORE

OPERATING THIS EQUIPMENT.

WARNING - TO REDUCE RISK OF

FIRE OR ELECTRICAL SHOCK, DO

NOT EXPOSE THIS EQUIPMENT TO

RAIN OR MOISTURE.

The lightning flash with arrowhead,

within an equilateral triangle, is intended

to alert the user to the presence of

uninsulated “dangerous voltage” within

the product’s enclosure that may be of

sufficient magnitude to constitute a risk

of electric shock to persons.

NO USER-SERVICEABLE PARTS

INSIDE. REFER SERVICING TO

QUALIFIED PERSONNEL.

To prevent the risk of electric shock, do not remove cover or

back. No user serviceable parts inside.

The exclamation point within an equi-

lateral triangle is intended to alert the

user to the presence of important

operating and maintenance (servic-

ing) instructions in the literature ac-

companying the appliance.

General:

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Warning: To reduce risk of fire or electrical shock,

do not expose this equipment to rain or moisture.

This unit is capable of producing high sound pres-

sure levels. Continued exposure to high sound pres-

sure levels can cause permanent hearing impair-

ment or loss. User caution is advised and ear protec-

tion is recommended when playing at high volumes.

6. Caution: to prevent electrical shock do not use this

(polarized) plug with an extension cord, receptacle

or other outlet unless the blades can be fully in-

serted to prevent blade exposure.

 Attention: pour pevenir les chocs elecriques pas

utiliser cette fiche polarisee avec un prolongateur,

une prise de courant ou un autre sortie de courant,

sauf si les lames peuvent etre inserees afond ans en

laisser aucune partie a decouvert.

7. Unplug this equipment during lightning storms or

when unused for long periods of time.

8. Only use attachments/accessories specified by the

manufacturer.

Installation:

9. The equipment shall be installed near the AC Socket

Outlet and the disconnect device shall be easily acces-

sible.

10. Do not block any ventilation openings. Install in accor-

dance with the manufacturer’s instructions.

11. Do not install near any heat sources such as radiators,

heat registers, stoves, or other equipment (including

amplifiers) that produce heat.

12. Do not use this equipment near water.

13. Do not expose this equipment to dripping or splashing

and ensure that no objects filled with liquids, such as

vases, are placed on the equipment.

14. Use only with the cart, stand, tripod,

bracket, or table specified by the manu-

facturer, or sold with the equipment.

When a cart is used, use caution when

moving the cart/equipment combination

to avoid injury from tip-over.

Connection:

15. Connect this equipment only to the type of AC power

source as marked on the unit.

16. Protect the power cord from being walked on or

pinched particularly at plugs, convenience receptacles,

and the point where they exit from the equipment.

17. Do not defeat the safety purpose of the polarized or

grounding-type plug.

Содержание MC126

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 FAX 607 724 0549 Owner s Manual MC126 MC126 Power Amplifier...

Страница 2: ...tacle or other outlet unless the blades can be fully in serted to prevent blade exposure Attention pour pevenir les chocs elecriques pas utiliser cette fiche polarisee avec un prolongateur une prise d...

Страница 3: ...ock or other hazards 26 Upon completion of any service or repairs to this prod uct ask the service technician to perform safety checks to determine that the product is in proper operating condition Cu...

Страница 4: ...ilable from the McIntosh Parts Department Power Control Cable Part No 170 202 Six foot 2 conductor shielded with two 1 8 inch stereo mini phone plugs 2 For additional connection information refer to t...

Страница 5: ...ion on the next page pertaining to installing the MC126 into cabinets Dimensions 17 1 2 44 45cm 6 5 16 16 03cm 7 5 8 19 37cm 18 1 2 46 99cm 3 16 0 48cm 13 1 4 33 66cm 17 43 18cm Front View of the MC12...

Страница 6: ...onents are installed in a single cabinet a quiet run ning ventilation fan can be a definite as set in maintaining all the system com ponents at the coolest possible op erating temperature A custom cab...

Страница 7: ...the POWER CONTROL OUT sends that turn On Off signal to the next McIntosh component Loudspeaker OUPUT Connections for Stereo and Mono Bridge Modes of Operation for each pair of channels Main Fuse hold...

Страница 8: ...tor Spade lug or prepared wire connection Insert the spade lug connector or prepared section of the cable end into the terminal side access hole and tighten the terminal cap until the cable is firmly...

Страница 9: ...he MC126 for Six Channels Right Front Loudspeaker Left Front Loudspeaker Center Front Loudspeaker Right Surround Loudspeaker Left Surround Loudspeaker Back Surround Loudspeaker McIntosh A V Control Ce...

Страница 10: ...ector or prepared section of the cable end into the terminal side access hole and tighten the termi nal cap until the cable is firmly clamped into the terminal so the wires cannot slip out Refer to fi...

Страница 11: ...11 How to Connect the MC126 for Three Channels To AC Outlet Right Front Loudspeaker 8 ohm Center Front Loudspeaker 8 ohm Left Front Loudspeaker 8 ohm McIntosh A V Control Center...

Страница 12: ...nd or RIGHT SURRound Amplifier Channel POWER GUARD Circuit activates POWER Switch Turns AC power On Off Remote On Indicator lights when the amplifier is in the Remote Turn On Mode POWER GUARD LEDs lig...

Страница 13: ...y is required for other applications set the controls as desired Refer to figure 10 Mode Switch The MODE Switch allows a pair of MC126 channels to be used in two different operating configura tions Re...

Страница 14: ...rated output Intermodulation Distortion Maximum Intermodulation Distortion if instanta neous peak output per channel does not exceed twice the rated output for any combination of fre quencies from 20H...

Страница 15: ...g damage Use the original shipping carton and interior parts only if they are all in good serviceable condition If a shipping carton or any of the interior part s are needed please call or write Custo...

Страница 16: ...McIntosh Part No 040650 McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903...

Отзывы: