![McGuire MEDLF Series Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/mcguire/medlf-series/medlf-series_user-manual_1754884031.webp)
29
4111-0026 — Feb. 2019
© 2019 Systems, LLC
Periodic Maintenance
MAINTENANCE
Weekly Maintenance
• Operate the dock leveler through the complete
operating cycle to maintain lubrication.
• Inspect the platform hinge and the lip hinge areas.
The hinge areas must be kept free of dirt and
debris. Build-up of foreign material in the hinge
areas will increase wear and cause abnormal
operation.
• Inspect warning decals and placards. Replace if
damaged or missing.
• Check bumpers for more than 1” of wear. Replace
worn, loose, damaged or missing bumpers.
Quarterly Maintenance
• Perform Weekly Maintenance.
• Inspect welds for cracks or damage, and inspect lip
and rear hinge pins. Repair or replace damaged
or cracked parts as needed.
• Lubricate the following areas with light-weight
machine oil:
(
A
) — Linkage arm pivots
(
B
) — Extend link arm pivot
(
C
) — Torsion bearing
(
D
) — Torsion bar pivot
(
E
) — Operating linkage pivots
• Lubricate the following areas with white lithium
grease:
(
F
) — Lip plate grease fittings
(
G
) — Base plate grease fittings
Failure to properly lubricate the dock leveler will
cause abnormal operation of the leveler.
Figure 18
E
G
F
B
A
C
D
8435 Units
E