Adjusting Heater Temperature
Turn knob to desired temperature. Measure the heater surface
temperature with a pyrometer. Any variance must be corrected to the
pyrometer reading.
Loosen setscrew in the knob. Turn knob to point to the same
temperature as the pyrometer. Tighten setscrew in the knob.
Turn knob to desired temperature. Allow heater to stabilize at the new
temperature (5 to 10 minutes) after adjusting.
The thermometer on the heater body indicates internal temperature and
should be used as a reference only.
TX02009-3-13-02
PH
04
810
-10
-2
4-12
Heater Indicator Light
The heater has a red indicator light to the right of the
heater temperature knob. When the heater is turned on
and preheating the red light glows steadily until the set
temperature is reached. The red light then goes off and on
as the heater maintains temperature.
TX04534-10-24-12
PH
04
810
-10
-2
4-12
6 - 9
Maintenance