3 - 2
Operation
PH
04
73
0-10
-1-12
Moving Machine Into Position
Make sure all personnel are safely clear of the machine
before moving.
Move both track control levers forward to go in a straight
line. Release the levers to stop. Moving just the right track
forward turns the machine to the left. Moving just the left
track forward turns the machine to the right. There are
alternate track controls on the left side of the machine.
The track speed valve (A) is used to switch between low
speed/high torque and high speed/low torque. The machine
will not have torque available to turn in all conditions in high
speed.
TX04477-10-24-12
PH
02
29
0-
4-17
-0
2
A
PH
04
72
9-10
-1-12
Prepare Heater
Install butt fusion heater plates.
NOTICE:
Non-coated heaters should never be used without butt
fusion heater plates installed. Refer to the "Maintenance" section
of this manual for installation procedure.
Heater is not explosion proof. Operation of
heater in an explosive atmosphere without
necessary safety precautions will result in serious
injury or death.
If operating in an explosive atmosphere, heater should be brought
up to temperature in a safe environment, then unplugged before
entering the explosive atmosphere for fusion.
Ensure the heater cables are connected and switch the throttle to
High or Auto.
Refer to the section "Adjusting Heater Temperature" in the
Maintenance section of this manual for instructions on setting the
heater temperature.
TX04531-05-05-14
PH
04
79
6-10
-1-12
PH
04
78
9-10
-8-12
¡PELIGRO!