22
If the valves are open, the indicator light and the red button will switch off (ref.
F).
b)
FUEL CIRCUIT PRESSURE ALARM
When the fuel pressure falls below or rises above the value of the programmed
percentage (ref. Chapter 2.2), the Fuel indicator light will flash as the buzzer
sounds.
3.2 MOTOR ALARM OPERATION.
The CHT cylinder head temperature (ref. B) and oil temperature (ref. D) alarm
indicator lights come on when the temperatures exceed the programmed thresholds,
as well as the relative indicator light and buzzer.
The red motor oil pressure indicator light (ref. E) comes on in two different ways;
a)
FLASHING - when the pressure exceeds the programmed threshold.
b)
STEADY ON - when the pressure is below the programmed threshold.
Содержание SAFETY-FLY 700 P
Страница 1: ...FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS SAFETY FLY 700 P USER MANUAL UK NR 1017 2 MIT...
Страница 6: ...6 1 4 General description A B C D M A F G...
Страница 24: ...24 Fig 7 example of cylinder head temperature alarm...
Страница 32: ...32 UK...