MBT Vaca Shape Скачать руководство пользователя страница 7

               

                                                                                                                                             

 

5//22

 

                                                    All rights reserved 

 

Chapter 3 Technical Specifications 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Items 

Specifications 

Screen 

1. The host screen: 10.4 inch TFT color touch screen 

2. Handpiece 1 screen: 2.5 inch 

3. Handpiece 2 screen: 1.0 inch 

4. Handpiece 3 screen: 1.0 inch 

Safety test 

Real time online for safety test 

Vacuum pressure 

1) Absolute value:        15kPa -90kPa ; 

2) Relative value:        85kPa -10kPa   

Ultrasound frequency: 1MHz 

Ultrasound power: 60W (max) 

Ultrasound frequency: 40kHz 

Ultrasound power: 60W (max) 

Feature 

Wireless IC card management system 

Handpiece 

4 (fast connected and identify automatically) 

Electricity shock protection 

I Class    BF Type 

Input power supply 

AC230V

±10%,50Hz±1Hz/AC110V±10%,60Hz±1Hz

 

Input power 

600VA 

Net weight 

55kg 

Gross weight 

Paper packing: 65kg 

Physical dimension 

Length 95cm× Width 50cm× Height 170cm 

Package dimension 

Length 74cm×Width 78cm×Height 145cm 

Содержание Vaca Shape

Страница 1: ...1 User Manual...

Страница 2: ...ent 8 5 2 Handpiece 1 8 5 3 Handpiece 2 and Handpiece 3 10 5 4 Handpiece 4 12 5 5 Ultrasonic Frequency 13 5 6 IC Card 13 5 6 1 Issue User Card 14 5 6 2 Issue Unlock Card 14 5 6 3 IC Card Applications...

Страница 3: ...eserved Chapter 1 Equipment Parts 1 1 Parts Power supply Earth ground Footswitch Electricity breaker Handpiece 1 Power switch Emergency switch 10 4 inch touch color screen Handpiece 3 Handpiece 2 Hand...

Страница 4: ...st 1 Handpiece 1 1 Handpiece 2 1 Handpiece 3 1 Power line 1 Handpiece 4 1 Quick plug 2 Handpiece stand Left Filter element extractor 1 Handpiece stand Right O Shape ring 10 Fuse 2 Grounding wire 1 Foo...

Страница 5: ...machine s operation and know how to turn off equipment in time If the machine is in danger press the emergency switch to cut off power supply 6 There is dangerous high voltage in the equipment So no o...

Страница 6: ...Picture 2 2 2 Picture 2 2 3 2 4 Environmental Request 1 Air quality System shall work in the environment which has no corrosive substances like acid dust and so on 2 Temperature and humidity Work tem...

Страница 7: ...90kPa 2 Relative value 85kPa 10kPa Ultrasound frequency 1MHz Ultrasound power 60W max Ultrasound frequency 40kHz Ultrasound power 60W max Feature Wireless IC card management system Handpiece 4 fast c...

Страница 8: ...s fixed well on the equipment 3 Disassemble Pull the handle Picture 4 1 2 at the same time take out the handpiece stand 4 The stand installation and disassemble of the two sides are the same 4 2 Fast...

Страница 9: ...and the other is smaller Insert the tip into the handle Picture 4 4 1 2 Slightly turn the tip Picture 4 4 2 4 5 Earth Ground Wire Installation it could not be turned on unless it is pressed It is eart...

Страница 10: ...t means handpiece is well connected 5 2 Handpiece 1 In Picture 5 2 1 A Standby B Ready C Work time D Cavitation energy output E Vacuum level F Absolute vacuum G Pulse time a Press key to select item t...

Страница 11: ...just it on the handpiece too ii To adjust vacuum energy level Touch and it turns to Press or to adjust it You can adjust it on the handpiece too iii To adjust pulse delay Touch and it turns to Press o...

Страница 12: ...equipment To stop timing function of IC card Issue a unlock card referring to 5 5 2 Make unlock card touch response area of the equipment 5 3 Handpiece 2 and Handpiece 3 Handpiece 2 Handpiece 3 Pictu...

Страница 13: ...vel Monopolar cavitaiton is 10 50W bipolar cavitation is 10 60W You can adjust cavitation energy level by handpiece key too E area Press to change to situation F area shows its available treatment par...

Страница 14: ...Press to change to situation F area shows its available treatment parts Touch the picture you want and the treatment manner will be showed at J area Picture 5 4 3 G area adopts countdown Press or to...

Страница 15: ...llow Picture 5 5 2 3 Bipolar cavitation of handpiece 1 is adjusted together 4 Bipolar cavitation of handpiece 2 is adjusted separately choose the left one or right one by touching picture Picture 5 5...

Страница 16: ...the blank card touch the card response area the system will issue user card automatically The screen will show Issue OK or Issue Error You can issue many user cards at a time Press to exit issuing int...

Страница 17: ...the equipment again If the customer wants to buy the equipment the agency gives the key card to him after charging 2 For beauty salon The beauty salon wants to charge according to treatment times For...

Страница 18: ...and clean it In Picture 6 1 1 A is filter element extractor B is filter element Procedure 1 Insert filter element extractor into the filter element as Picture 6 1 2 shows Then take out the filter ele...

Страница 19: ...well abutting joint 4 Screw A and B Picture 6 2 1 6 3 Emergency Switch Turn on the equipment when you press the emergency switch the system will turn off at once Turn the emergency switch and start th...

Страница 20: ...h touch screen Contact with us Touch screen has no display Trouble with touch screen Contact with us No vacuum or less vacuum Trouble with vacuum pump Contact with us Trouble with AC contactor Contact...

Страница 21: ...mellitus and so on 3 Pregnancy and lactation in the first 6 months 4 Open wound or abnormal wound healing 5 Menstrual period 6 Osteoporosis 8 4Notes of Using Cavitation Handpiece 1 Keep moving the tip...

Страница 22: ...dpiece 2 Handpiece 4 Handpiece 1 Handpiece 2 Handpiece 4 big tip Belly 30 40 minutes 15 20 minutes 5 8 minutes Hip 15 20 minutes 15 20 minutes 3 5 minutes Leg 15 30 minutes 15 30 minutes 10 15 minutes...

Страница 23: ...ge toxin and fat as well as improve blood circulation After treatment the customer feels relax and happy which normal massage could not realize At the same time handpiece 1 could help to realize good...

Страница 24: ...After treatment some skin turns red in several minutes or 1 hour some skin appears red measles which disappears in 2 3 days During treatment most people feel so comfortable that they fall asleep Many...

Отзывы: