Try the following:

 

Check to see if a household fuse has blown or circuit breaker 
has tripped. Electric dryers use two household fuses or 
breakers. Replace the fuse or reset the circuit breaker. 

Confirm the power cord is properly installed. Refer to “Electrical 
Connection” for details.

Select a Timed Dry heated cycle, and restart the dryer.

If the message persists, consult a qualified electrician.

“AF” (low airflow condition):

 

The dryer will continue to run when this diagnostic code is 
present. Press any key to clear the code from the display and 
return to the estimated time remaining.

Try the following:

Clean lint screen. 

Check to see if the vent run from the dryer to the wall is 
crushed or kinked. 

Confirm the vent run from the dryer to the wall is free of lint 
and debris.

Confirm the exterior vent exhaust hood is free of lint and 
debris.

Confirm your vent system falls within the recommended run 
length and number of elbows for the type of vent you are 
using. Refer to “Plan Vent System” for details.

Select a Timed Dry heated cycle, and restart the dryer.

If the message persists, have your entire home venting run 
cleaned.

“E” Variable (E1, E2, E3) service codes:

 

Call for service.

Dryer Results

Clothes are not drying satisfactorily, drying times are too 
long, or load is too hot

Is the lint screen clogged with lint?

 

 

Lint screen should be cleaned before each load.

 

Is the exhaust vent or outside exhaust hood clogged with 
lint, restricting air movement?

 

 

Run the dryer for 5-10 minutes. Hold your hand under the 
outside exhaust hood to check air movement. If you do not feel 
air movement, clean exhaust system of lint or replace exhaust 
vent with heavy metal or flexible metal vent. See the Installation 
Instructions.

Are fabric softener sheets blocking the grille?

 

 

Use only one fabric softener sheet, and use it only once.

Is the exhaust vent the correct length?

 

 

Check that the exhaust vent is not too long or has too many 
turns. Long venting will increase drying times. See the 
Installation Instructions. 

Is the exhaust vent diameter the correct size?

 

 

Use 4" (102 mm) diameter vent material.

Is the dryer located in a room with temperature below 

 

45ºF (7ºC)?

 

 

Proper operation of dryer cycles requires temperatures above 
45ºF (7ºC).

Is the dryer located in a closet?

 

 

Closet doors must have ventilation openings at the top and 
bottom of the door. The front of the dryer requires a minimum of 
1" (25 mm) of airspace, and, for most installations, the rear of the 
dryer requires 5" (127 mm). See the Installation Instructions.

W10471644B
W10471646B - SP

© 2012 Whirlpool Corporation.

All rights reserved.

01/12

Printed in U.S.A.

Содержание WED9470WW

Страница 1: ...SP DRYER SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important ...

Страница 2: ...package from dryer drum Check that all parts are included NOTE Do not use leveling legs supplied with dryer if installing on a pedestal Steam Models A Leveling legs 4 B Y connector C Short inlet hose D Long inlet hose E Rubber washer Remove parts package from dryer drum Check that all parts are included NOTE Do not use leveling legs supplied with dryer if installing on a pedestal Parts needed Chec...

Страница 3: ...yer and water pressure of 20 100 psi 137 9 689 6 kPa You may use the cold water supply from your washer using the Y connector provided Do not operate your dryer at temperatures below 45ºF 7ºC At lower temperatures the dryer might not shut off at the end of an automatic sensor cycle This can result in longer drying times The dryer must not be installed or stored in an area where it will be exposed ...

Страница 4: ... the door are required Louvered doors with equivalent ventilation openings are acceptable Companion appliance spacing should also be considered Custom undercounter installation Dryer only A B C D E Steam Electric or Gas Non Steam Electric or Gas A 0 0 mm 0 0 mm B 38 965 mm 38 965 mm C 1 25 mm 1 25 mm D 27 686 mm 27 686 mm E 1 25 mm 1 25 mm Required spacing NOTE Some models are not recommended for ...

Страница 5: ...equirements This dryer is suitable for mobile home installations The installation must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or Standard CAN CSA Z240 MH Mobile home installations require All Dryers Metal exhaust system hardware which is available for purcha...

Страница 6: ...led in a location where grounding through the neutral conductor is prohibited Grounding through the neutral is prohibited for 1 new branch circuit installations 2 mobile homes 3 recreational vehicles and 4 areas where local codes prohibit grounding through the neutral conductors If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should con...

Страница 7: ... terminal block opening C Clamp section D Strain relief tab pointing down A B C D Put power supply cord through the strain relief Be sure that the wire insulation on the power supply cord is inside the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Do not further tighten strain relief screws at this point Style 2 Direct wire strain re...

Страница 8: ...connection Direct Wire Electrical Connection Options If local codes do not permit the connection of a cabinet ground conductor to the neutral wire go to Optional 3 wire connection section 4 wire connection Power supply cord IMPORTANT A 4 wire connection is required for mobile homes and where local codes do not permit the use of 3 wire connections A B F E G D C A 4 wire receptacle NEMA type 14 30R ...

Страница 9: ...m When connecting to the terminal block place the hooked end of the wire under the screw of the terminal block hook facing right squeeze hooked end together and tighten screw as shown 1 Remove center terminal block screw 2 Remove neutral ground wire from external ground conductor screw Connect neutral ground wire and place the hooked end hook facing right of the neutral wire white or center wire o...

Страница 10: ...r with hold down screw 6 You have completed your electrical connection Now go to Venting Requirements 3 wire connection Direct wire Use where local codes permit connecting cabinet ground conductor to neutral wire Direct wire cable must have 5 ft 1 52 m of extra length so dryer can be moved if needed Strip 31 2 89 mm of outer covering from end of cable Strip insulation back 1 25 mm If using 3 wire ...

Страница 11: ...l ground conductor screw to an adequate ground VENTING Venting Requirements WARNING To reduce the risk of fire this dryer MUST BE EXHAUSTED OUTDOORS IMPORTANT Observe all governing codes and ordinances The dryer exhaust must not be connected into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building If using an existing vent system Clean lint from the entire length ...

Страница 12: ...Angled hood style An exhaust hood should cap the vent to keep rodents and insects from entering the home Exhaust hood must be at least 12 305 mm from the ground or any object that may be in the path of the exhaust such as flowers rocks or bushes snow line etc Do not use an exhaust hood with a magnetic latch Plan Vent System Choose your exhaust installation type Recommended exhaust installations Ty...

Страница 13: ...ength and elbows needed for best drying performance Use the following vent system chart to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in the Vent system chart Exhaust systems longer than those specified will Shorten the life of the dryer Reduce performance resulting in longer drying times and increased energy usage ...

Страница 14: ... replace with new rubber washer provided If space permits attach the brass female end of the Y connector to the cold water faucet NOTE If Y connector can be attached directly to cold water faucet go to Step 6 If Y connector cannot be attached directly to the cold water faucet the short hose must be used Continue with Step 3 3 Attach short hose to cold water faucet Screw on coupling by hand until i...

Страница 15: ...ceive an L2 code there may be a problem with your home power supply keeping the dryer s heater from turning on See Troubleshooting 14 When the dryer has been running for 5 minutes open the dryer door and feel for heat If you feel heat cancel cycle and close the door If you do not feel heat turn off the dryer and check the following There may be 2 household fuses or circuit breakers for the dryer C...

Страница 16: ...hes are not drying satisfactorily drying times are too long or load is too hot Is the lint screen clogged with lint Lint screen should be cleaned before each load Is the exhaust vent or outside exhaust hood clogged with lint restricting air movement Run the dryer for 5 10 minutes Hold your hand under the outside exhaust hood to check air movement If you do not feel air movement clean exhaust syste...

Отзывы: