background image

14

2.

Firmly grasp the body of the dryer (not the console panel). Gently 
lay the dryer on the cardboard. See illustration.  

3.

Examine the leveling legs. Find the diamond marking. 

4.

Screw the legs into the leg holes by hand. Use a wrench to finish 
turning the legs until the diamond marking is no longer visible.

5.

Place a carton corner post from dryer packaging under each of 
the 2 dryer back corners. Stand the dryer up. Slide the dryer on 
the corner posts until it is close to its final location. Leave enough 
room to connect the exhaust vent.

CONNECT VENT

1.

Using a 4" (102 mm) clamp, connect vent to exhaust outlet in 
dryer. If connecting to existing vent, make sure the vent is clean. 
The dryer vent must fit over the dryer exhaust outlet and inside the 
exhaust hood. Check that the vent is secured to exhaust hood 
with a 4" (102 mm) clamp.

2.

Move dryer into its final location. Do not crush or kink vent.

3.

Once the exhaust vent connection is made, remove the corner 
posts and cardboard.

CONNECT INLET HOSE 

(STEAM MODELS)

The dryer must be connected to the cold water faucet using the new 
inlet hoses. Do not use old hoses.

1.

Turn cold water faucet off and remove washer inlet hose.

2.

Remove old rubber washer from inlet hose and replace with new 
rubber washer provided. If space permits, attach the brass female 
end of the “Y” connector to the cold water faucet.

NOTE:

 If “Y” connector can be attached directly to cold water 

faucet, go to Step 6. If “Y” connector cannot be attached 
directly to the cold water faucet, the short hose must be used. 
Continue with Step 3.

3.

Attach short hose to cold water faucet. Screw on coupling by 
hand until it is seated on faucet. 

4.

Using pliers, tighten the couplings with an additional two-thirds 
turn. 

NOTE:

 Do not overtighten. Damage to the coupling can result.

5.

Attach “Y” connector to brass male end of small hose. Screw on 
coupling by hand until it is seated on connector.

6.

One end of the long hose has a wire mesh strainer inside the 
coupling. Attach this end to the “Y” connector.

7.

Attach washer cold inlet hose to other end of “Y” connector. 
Screw on coupling by hand until it is seated on connector.

A

 

A. Inlet to cold water

8.

Using pliers, tighten the couplings an additional two-thirds turn.

NOTE:

 Do not overtighten. Damage to the coupling can result.

9.

Attach other end of long hose to fill valve at bottom of dryer 
back panel. Screw on coupling by hand until it is seated on fill 
valve connector. 

10.

Using pliers, tighten the coupling an additional two-thirds turn.

NOTE:

 Do not overtighten. Damage to the coupling can result.

11.

Check that the water faucets are on.

12.

Check for leaks around “Y” connector, faucet, and hoses. 

Содержание WED9470WW

Страница 1: ...SP DRYER SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important ...

Страница 2: ...package from dryer drum Check that all parts are included NOTE Do not use leveling legs supplied with dryer if installing on a pedestal Steam Models A Leveling legs 4 B Y connector C Short inlet hose D Long inlet hose E Rubber washer Remove parts package from dryer drum Check that all parts are included NOTE Do not use leveling legs supplied with dryer if installing on a pedestal Parts needed Chec...

Страница 3: ...yer and water pressure of 20 100 psi 137 9 689 6 kPa You may use the cold water supply from your washer using the Y connector provided Do not operate your dryer at temperatures below 45ºF 7ºC At lower temperatures the dryer might not shut off at the end of an automatic sensor cycle This can result in longer drying times The dryer must not be installed or stored in an area where it will be exposed ...

Страница 4: ... the door are required Louvered doors with equivalent ventilation openings are acceptable Companion appliance spacing should also be considered Custom undercounter installation Dryer only A B C D E Steam Electric or Gas Non Steam Electric or Gas A 0 0 mm 0 0 mm B 38 965 mm 38 965 mm C 1 25 mm 1 25 mm D 27 686 mm 27 686 mm E 1 25 mm 1 25 mm Required spacing NOTE Some models are not recommended for ...

Страница 5: ...equirements This dryer is suitable for mobile home installations The installation must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or Standard CAN CSA Z240 MH Mobile home installations require All Dryers Metal exhaust system hardware which is available for purcha...

Страница 6: ...led in a location where grounding through the neutral conductor is prohibited Grounding through the neutral is prohibited for 1 new branch circuit installations 2 mobile homes 3 recreational vehicles and 4 areas where local codes prohibit grounding through the neutral conductors If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should con...

Страница 7: ... terminal block opening C Clamp section D Strain relief tab pointing down A B C D Put power supply cord through the strain relief Be sure that the wire insulation on the power supply cord is inside the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Do not further tighten strain relief screws at this point Style 2 Direct wire strain re...

Страница 8: ...connection Direct Wire Electrical Connection Options If local codes do not permit the connection of a cabinet ground conductor to the neutral wire go to Optional 3 wire connection section 4 wire connection Power supply cord IMPORTANT A 4 wire connection is required for mobile homes and where local codes do not permit the use of 3 wire connections A B F E G D C A 4 wire receptacle NEMA type 14 30R ...

Страница 9: ...m When connecting to the terminal block place the hooked end of the wire under the screw of the terminal block hook facing right squeeze hooked end together and tighten screw as shown 1 Remove center terminal block screw 2 Remove neutral ground wire from external ground conductor screw Connect neutral ground wire and place the hooked end hook facing right of the neutral wire white or center wire o...

Страница 10: ...r with hold down screw 6 You have completed your electrical connection Now go to Venting Requirements 3 wire connection Direct wire Use where local codes permit connecting cabinet ground conductor to neutral wire Direct wire cable must have 5 ft 1 52 m of extra length so dryer can be moved if needed Strip 31 2 89 mm of outer covering from end of cable Strip insulation back 1 25 mm If using 3 wire ...

Страница 11: ...l ground conductor screw to an adequate ground VENTING Venting Requirements WARNING To reduce the risk of fire this dryer MUST BE EXHAUSTED OUTDOORS IMPORTANT Observe all governing codes and ordinances The dryer exhaust must not be connected into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building If using an existing vent system Clean lint from the entire length ...

Страница 12: ...Angled hood style An exhaust hood should cap the vent to keep rodents and insects from entering the home Exhaust hood must be at least 12 305 mm from the ground or any object that may be in the path of the exhaust such as flowers rocks or bushes snow line etc Do not use an exhaust hood with a magnetic latch Plan Vent System Choose your exhaust installation type Recommended exhaust installations Ty...

Страница 13: ...ength and elbows needed for best drying performance Use the following vent system chart to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in the Vent system chart Exhaust systems longer than those specified will Shorten the life of the dryer Reduce performance resulting in longer drying times and increased energy usage ...

Страница 14: ... replace with new rubber washer provided If space permits attach the brass female end of the Y connector to the cold water faucet NOTE If Y connector can be attached directly to cold water faucet go to Step 6 If Y connector cannot be attached directly to the cold water faucet the short hose must be used Continue with Step 3 3 Attach short hose to cold water faucet Screw on coupling by hand until i...

Страница 15: ...ceive an L2 code there may be a problem with your home power supply keeping the dryer s heater from turning on See Troubleshooting 14 When the dryer has been running for 5 minutes open the dryer door and feel for heat If you feel heat cancel cycle and close the door If you do not feel heat turn off the dryer and check the following There may be 2 household fuses or circuit breakers for the dryer C...

Страница 16: ...hes are not drying satisfactorily drying times are too long or load is too hot Is the lint screen clogged with lint Lint screen should be cleaned before each load Is the exhaust vent or outside exhaust hood clogged with lint restricting air movement Run the dryer for 5 10 minutes Hold your hand under the outside exhaust hood to check air movement If you do not feel air movement clean exhaust syste...