ELECTRIC DRYER INSTALLATION INSTRUCTIONS  

U.S.A. ONLY

Para una versión de estas instrucciones en español, visite www.Whirlpool.com

TABLE OF CONTENTS

DRYER SAFETY..............................................................................1

INSTALLATION REQUIREMENTS ................................................2

Tools and Parts ............................................................................2
Optional Equipment .....................................................................3
Location Requirements................................................................3

ELECTRIC DRYER POWER HOOKUP .........................................5

Electrical Requirements ...............................................................5
Electrical Connection ...................................................................6

VENTING .......................................................................................11

Venting Requirements................................................................11

Plan Vent System .......................................................................12
Install Vent System.....................................................................13

INSTALL LEVELING LEGS...........................................................13

CONNECT VENT...........................................................................14

CONNECT INLET HOSE (STEAM MODELS)..............................14

LEVEL DRYER ..............................................................................15

COMPLETE INSTALLATION .......................................................15

TROUBLESHOOTING ..................................................................15

W10471644B
W10471646B - SP

DRYER SAFETY

You can be killed or seriously injured if you don't immediately 
 

You

 

can be killed or seriously injured if you don't follow 

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety 
messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”

These words mean:

follow instructions.

instructions.

DANGER

WARNING

Содержание WED9470WW

Страница 1: ...SP DRYER SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important ...

Страница 2: ...package from dryer drum Check that all parts are included NOTE Do not use leveling legs supplied with dryer if installing on a pedestal Steam Models A Leveling legs 4 B Y connector C Short inlet hose D Long inlet hose E Rubber washer Remove parts package from dryer drum Check that all parts are included NOTE Do not use leveling legs supplied with dryer if installing on a pedestal Parts needed Chec...

Страница 3: ...yer and water pressure of 20 100 psi 137 9 689 6 kPa You may use the cold water supply from your washer using the Y connector provided Do not operate your dryer at temperatures below 45ºF 7ºC At lower temperatures the dryer might not shut off at the end of an automatic sensor cycle This can result in longer drying times The dryer must not be installed or stored in an area where it will be exposed ...

Страница 4: ... the door are required Louvered doors with equivalent ventilation openings are acceptable Companion appliance spacing should also be considered Custom undercounter installation Dryer only A B C D E Steam Electric or Gas Non Steam Electric or Gas A 0 0 mm 0 0 mm B 38 965 mm 38 965 mm C 1 25 mm 1 25 mm D 27 686 mm 27 686 mm E 1 25 mm 1 25 mm Required spacing NOTE Some models are not recommended for ...

Страница 5: ...equirements This dryer is suitable for mobile home installations The installation must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or Standard CAN CSA Z240 MH Mobile home installations require All Dryers Metal exhaust system hardware which is available for purcha...

Страница 6: ...led in a location where grounding through the neutral conductor is prohibited Grounding through the neutral is prohibited for 1 new branch circuit installations 2 mobile homes 3 recreational vehicles and 4 areas where local codes prohibit grounding through the neutral conductors If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should con...

Страница 7: ... terminal block opening C Clamp section D Strain relief tab pointing down A B C D Put power supply cord through the strain relief Be sure that the wire insulation on the power supply cord is inside the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Do not further tighten strain relief screws at this point Style 2 Direct wire strain re...

Страница 8: ...connection Direct Wire Electrical Connection Options If local codes do not permit the connection of a cabinet ground conductor to the neutral wire go to Optional 3 wire connection section 4 wire connection Power supply cord IMPORTANT A 4 wire connection is required for mobile homes and where local codes do not permit the use of 3 wire connections A B F E G D C A 4 wire receptacle NEMA type 14 30R ...

Страница 9: ...m When connecting to the terminal block place the hooked end of the wire under the screw of the terminal block hook facing right squeeze hooked end together and tighten screw as shown 1 Remove center terminal block screw 2 Remove neutral ground wire from external ground conductor screw Connect neutral ground wire and place the hooked end hook facing right of the neutral wire white or center wire o...

Страница 10: ...r with hold down screw 6 You have completed your electrical connection Now go to Venting Requirements 3 wire connection Direct wire Use where local codes permit connecting cabinet ground conductor to neutral wire Direct wire cable must have 5 ft 1 52 m of extra length so dryer can be moved if needed Strip 31 2 89 mm of outer covering from end of cable Strip insulation back 1 25 mm If using 3 wire ...

Страница 11: ...l ground conductor screw to an adequate ground VENTING Venting Requirements WARNING To reduce the risk of fire this dryer MUST BE EXHAUSTED OUTDOORS IMPORTANT Observe all governing codes and ordinances The dryer exhaust must not be connected into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building If using an existing vent system Clean lint from the entire length ...

Страница 12: ...Angled hood style An exhaust hood should cap the vent to keep rodents and insects from entering the home Exhaust hood must be at least 12 305 mm from the ground or any object that may be in the path of the exhaust such as flowers rocks or bushes snow line etc Do not use an exhaust hood with a magnetic latch Plan Vent System Choose your exhaust installation type Recommended exhaust installations Ty...

Страница 13: ...ength and elbows needed for best drying performance Use the following vent system chart to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in the Vent system chart Exhaust systems longer than those specified will Shorten the life of the dryer Reduce performance resulting in longer drying times and increased energy usage ...

Страница 14: ... replace with new rubber washer provided If space permits attach the brass female end of the Y connector to the cold water faucet NOTE If Y connector can be attached directly to cold water faucet go to Step 6 If Y connector cannot be attached directly to the cold water faucet the short hose must be used Continue with Step 3 3 Attach short hose to cold water faucet Screw on coupling by hand until i...

Страница 15: ...ceive an L2 code there may be a problem with your home power supply keeping the dryer s heater from turning on See Troubleshooting 14 When the dryer has been running for 5 minutes open the dryer door and feel for heat If you feel heat cancel cycle and close the door If you do not feel heat turn off the dryer and check the following There may be 2 household fuses or circuit breakers for the dryer C...

Страница 16: ...hes are not drying satisfactorily drying times are too long or load is too hot Is the lint screen clogged with lint Lint screen should be cleaned before each load Is the exhaust vent or outside exhaust hood clogged with lint restricting air movement Run the dryer for 5 10 minutes Hold your hand under the outside exhaust hood to check air movement If you do not feel air movement clean exhaust syste...