9
3-wire Power Supply Cord Connection
use where local codes permit connecting cabinet-ground
conductor to neutral wire.
A
B
D
C
E
F
G
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with upturned ends
E. 3/4" (19 mm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
5.
Connect remaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw.
now, go to Venting Requirements.
Connect remaining wires
6.
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw.
now, go to Venting Requirements.
4.
Connect neutral wire
Connect neutral wire (white or center) (C) of power supply cord
to center, silver-colored terminal block screw (B). Tighten screw.
C
B
Remove center, silver-colored terminal block screw (B).
B
3.
Remove center screw
A
F
Connect ground wire (F) (green or bare) of power supply cord
to external ground conductor screw (A). Tighten screw.
5.
Connect ground wire