72
SECTION VIII
PHASE 7 OPL PROGRAMMING LIMITS
A. PREPROGRAMMED CYCLES
1. Automatic Drying Cycle
(Patent No. 4,827,627)
a. Drying Temperature from 160º F to 200º F (71º C to 93º C) in one-degree increments.
b. Cycle Adjustment Value from 0-99 in increments of one (1).
c. Cool Down Time from 0 to 99 minutes in 1 minute increments.
d. Cool Down Temperature from 70º F to 100º F (21º C to 38º C) in one-degree increments.
2. Timed (Manual) Drying Cycle
a. Drying Temperature from 100º F to 200º F (38º C to 93º C) in one-degree increments.
b. Drying Time from 0 to 99 minutes in 1 minute increments.
c. Cool Down Time from 0 to 99 minutes in 1 minute increments for preprogrammed cycle.
d. Cool Down Temperature from 70º F to 100º F (21º C to 38º C) in one-degree increments.
e. Reversing Models
1) Automatic Drying Cycle
(Patent No. 4,827,627)
Spin Time and Stop Time is not programmable.
(Refer to
Fixed Parameters
on next page).
2) Manual Timed Cycle
a) Spin Time (
“SPIN TIME”
) from 30-seconds to 120-seconds in 1-second increments.
b) Dwell (stop) Time (
“STOP TIME”
) from 5-seconds to 10-seconds in 1-second increments.