17
NOTE:
The dryer can be stopped at any time by pressing the “STOP/CLEAR”
O
key, at this time the
dryer will go into a cycle pause. If the “STOP/CLEAR”
O
key is pressed again at this point,
the cycle that was in progress
will
be
cancelled and returned to the “READY” state.
8) Once the programmed drying time has expired, the Phase 7 OPL microprocessor controller (computer)
will proceed into the Cool Down Cycle (mode).
9) Once the Cool Down Cycle begins at the end of the heat cycle, the light emitting diode (L.E.D.)
display will read COOL DOWN TEMP ___/___ MINUTES REMAINING. At the end of the
heat cycle, the dryer will shut off the heat and continue the fan and basket (tumbler) until the Cool
Down Time or temperature is reached.
10) Once the Cool Down Cycle is completed, the Phase 7 OPL microprocessor controller (computer)
will proceed into the Wrinkle Guard Cycle. The Audio Alert tone will sound (for amount set in
Audio Alert On Time). The L.E.D. display will read “WRINKLE GUARD.” The times are fixed
at 2 minutes OFF, 2 minutes ON for a maximum time of 99 minutes. These times are not
programmable. During the ON time, the blower (fan) and the basket (tumbler) will start to rotate
(without heat for 2 minutes). The Phase 7 OPL microprocessor controller (computer) will repeat
this process until the Maximum Wrinkle Guard On Time has expired (99 minutes). The L.E.D.
display will then read “CYCLE DONE” and lockout the dryer functions until the doors are opened.
It will then return to “READY.”
B. OPERATING NOTES
1. Steam injection will only operate when dryer is running.
2. The RPM of the basket (tumbler) can be displayed by pressing and holding the “DOWN ARROW” key
while a cycle is in progress. If cycle has not been started, the display will read CPU Board Voltage Value.
(23-26 Volts is normal).
3. The dryer can be stopped at any time by pressing the “STOP/CLEAR”
O
key, at this time the dryer will go
into a cycle pause. If the “STOP/CLEAR”
O
key is pressed again at this point, the cycle that was in
progress will be cancelled and returned to the “READY” state.
4. When programming a Manually Loaded Cycle, if an error is made making an entry, press the “STOP/
CLEAR”
O
key ONCE, and the entry will be cancelled. Reenter the selection. If the selection is entered
and an error is made, the “STOP/CLEAR”
O
key will cancel the program and return to the “READY”
state.
5. Use the “UP ARROW” and “DOWN ARROW” to scroll through menus or increase/decrease number
values or toggle between choices.
Содержание PHASE 7.2