Maytag Neptune FAV7500A Скачать руководство пользователя страница 11

Troubleshooting

 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury, or death, disconnect power before servicing, unless testing 
requires it. 
 

 

©2005 Maytag Services 

 

16023174

 

11

Special Instructions Water Leak Around Pulley On 
Tub Bottom 

Water leaking around the pulley on the bottom of the 
tub, check the following: 

 
1.  Remove the Transmission. The Transmission 

should be approx. 1/3 full of oil. The oil in the 
Transmission should be thick, similar to a high 
viscosity motor oil. Tip the Transmission slightly, 
the oil should move slowly. If the Transmission is 
nearly full or if the fluid is very thin and moves 
quickly, the Transmission has water in it. Replace 
the Transmission, O-Ring, Spinner Support, Tub 
Seal and Outer Tub. 

2.  If no water is inside the Transmission, check the 

integrity of the O-Ring. Look for signs of water or 
rust on and around the Input Shaft. If the O-Ring 
is bad or there are signs of water or rust around 
the input shaft, replace the spinner support, tub 
seal and the outer tub. 

 
 
 
 
 
 
 

Titan LED Washer Control Board Inputs Table

 

 
3.  If there was no water in the Transmission or 

around the top of the Input Shaft, it is likely the 
water was leaking through the Tub Seal. Replace 
the Outer Tub and Tub Seal. Inspect the Spinner 
Support for damage around the Tub Seal area. 
Replace the Spinner Support if it is damaged. 

4.  The Clutch Assembly should be inspected for 

signs of water or oil contamination. Clean Clutch 
Assembly as needed. Replace Clutch Assembly 
when water or oil contaminates the roller clutches. 

Note:

 Oil in a new Transmission is clear. During 

operation, the oil will turn a dark color caused by the 
special compounds in some of the bushings. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Item 

Description 

Voltage 

Input type 

Input to Where 

Comments

Water Valve 
Thermistor  

 

0 - 3.3 VDC 

Analog 

Input to Micro-
processor 

  

Power Cord  
 

Line 

120 VAC 

  

Input to some relays 

  

  

Neutral 

120 VAC 

  

Input to some relays 

  

  

Ground 

Chassis 
ground 

  

  

  

Lid Lock Switch  
 

This switch senses if the lid is 
locked 

0 - 12 VDC 

Digital 

Input to Micro-
processor and safety 
circuitry 

Closed when lid 
is locked

 

Lid Closed Switch  
 

This switch senses if the lid is 
closed 

0 - 12 VDC 

Digital 

Input to Micro-
processor and 
system relay coil 

Closed when lid 
is closed

 

User Interface 

Membrane switch key pad 

0 - 12 VDC 

Digital  

Input to Micro-
processor 

Open when key 
is not pressed

 

Tach from Variable 
Speed Motor Control 
 

Tach signal 

0 - 12 VDC 

Digital 

Input to Micro-
processor and safety 
circuitry 

 

Pressure switch 
 

Low water level 

0 - 12 VDC 

Digital 

Input to Micro-
processor 

Closed when not 
satisfied

 

  

Medium water level 

0 - 12 VDC 

Digital 

Input to Micro-
processor 

Closed when not 
satisfied

 

  

High water level 

120 VAC 

 

Input to Micro-
processor and some 
relays 

Closed when not 
satisfied

 

Содержание Neptune FAV7500A

Страница 1: ...ician for servicing or repair of this unit Refer to Service Manual 16022808 for detailed installation operating testing troubleshooting and disassembly instructions CAUTION All safety information must...

Страница 2: ...e Fabric cycles such as NORMAL DELICATES HAND WASH WRINKLE CONTROL only tumble periodically every 60 seconds Check for loose connections at machine control board motor control board and motor Perform...

Страница 3: ...itch circuit Circuit should be closed at machine control See board input output chart Check for loose electrical connections at lid lock and at machine control board Push lid closed to make sure nothi...

Страница 4: ...variety of special service tests and view diagnostic displays Enter Exit Service Mode To enter Service Mode press the Help and Back keys for three seconds or until the control beeps The motor speed w...

Страница 5: ...the Quick Spin Test option Quick Spin test steps are as follows 1 Lock the lid 2 Spin to index speed 90 rpm and hold for 60 seconds Pump drains machine 3 Spin to index speed 150 rpm and hold for 6 se...

Страница 6: ...no cycle running the Control Board will send a signal to the switch to unlock the lid If motor does not run Check for 120 VAC at the motor control board harness between L1 and Neutral See Illustration...

Страница 7: ...nce to next step if water is not connected to machine 13 Drain 14 Spin to 150 rpm 15 Spin to 350 rpm 16 Spin to 850 rpm 17 Pump cycles on and off 18 Coast to 0 rpm 19 Lid unlocks If a failure occurs d...

Страница 8: ...lanced load Go to Wet Clothes Troubleshooting Section Diag Code Description Trigger Action to be taken 11 Will not remember machine settings Difficulty in reading memory Go to Clear diagnostic codes D...

Страница 9: ...hine After five 5 minutes of inactivity user key presses in Service Mode the machine will exit the Service Mode and resume normal operations Pressing the Off key will completely exit Service Mode If a...

Страница 10: ...r and push down so sensor collapses to before the 1 mark molded on slider Display will show tub unbalance NOTE Moving the sensor midway between mark 1 and mark 2 represents normal operation Display wi...

Страница 11: ...damage around the Tub Seal area Replace the Spinner Support if it is damaged 4 The Clutch Assembly should be inspected for signs of water or oil contamination Clean Clutch Assembly as needed Replace C...

Страница 12: ...e of meter to the appropriate pin numbers listed in the chart Meter will show infinite unless the appropriate key is pressed Note When the Neptune TL is plugged in the Machine Control Board will check...

Страница 13: ...Wiring Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power before servicing unless testing requires it 2005 Maytag Services 16023174 13 9800...

Страница 14: ...Wiring Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to washer before servicing unless testing requires it 16023174 14 2005 Maytag Services 7500...