Troubleshooting
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power before servicing, unless testing
requires it.
16023174
©2005 Maytag Services
10
1
1
2
Tub Displacement Sensor Diagnostics
CAUTION:
Do not perform continuity check directly on
Displacement Sensor due to the potential for
damaging the microprocessor chip in the sensor.
1. Enter the Service Mode by pressing the
Help
and
Back
keys for three seconds.
2. Press
System Check
on the display
3. Push tub to back right corner so sensor extends
beyond the #2 mark molded on slider. Display will
show
“tub unbalance”
.
4. Pull tub to front left corner and push down so
sensor collapses to before the #1 mark molded on
slider. Display will show
“tub unbalance”
.
NOTE:
Moving the sensor midway between mark #1
and mark #2 represents normal operation.
Display will show
“no unbalance”.
Component Diagnostics
NOTE:
Unplug lower harness connector under
console and test from wire insertion side.
Insertion Side Lower Harness Connector
Component
Check
Pin Wire
Color
Range
Drain Pump
2 and 11
WH
and
RD/BK
0 to 30
Ohms
Pressure
Switch Low
Level
4 and 13 BR and
RD/W
H
0 to 20
Ohms (no
water in
machine)
Pressure
Switch Med
Level
13 and 14 PU and
RD/W
H
0 to 20
Ohms (no
water in
machine)
Pressure
Switch High
Level
1 and 9
GY/BK
and
YL/BL
0 to 20
Ohms (no
water in
machine)
Spinner Support Shaft Nut 64-80 ft. lbs. Special
wrench required.
Tub
Displacement
Sensor
#2 Mark
#1 Mark
Pin #14
Pin #9
Pin #8
Pin #1