Maytag MLG33PDAWW Скачать руководство пользователя страница 22

22

Maytag Co.

113413-1

!

!

!

!

!

Steam Requirements – High Pressure

Inlet ---- 1/2” N.P.T. supply line connection

1 at top manifold

Return - 1/2” N.P.T. return line connection

1 at bottom manifold

Shaded areas are stated in metric equivalents

* The minimum operating pressure for optimum results is 100 psig (689.47

kPa).

Installation Instructions

To ensure an adequate supply of steam is provided, be sure
that the steam supply lines and steam return lines are sized
and laid out as stipulated in this manual.  Inadequate steam
supply lines and steam return lines or improper steam
plumbing will result in poor performance and can cause
component failure.  Clean, dry steam must be provided to the
dryer.

Important

Steam coil failure due to water hammer by wet
steam will void the warranty.

The presence of condensate in the steam supply line will
cause water hammer and subsequent heat exchanger
(steam coil) failure.  The steam supply connection into the
main supply line must be made with a minimum 10-inch
(25.4 cm) riser.  This will prevent any condensate from draining
towards the dryer.

The steam supply line to the dryer must include a 12-inch
(30.48 cm) riser along with a drip trap and check valve.  This
will prevent any condensate from entering the steam coil.

Flexible hoses or couplings must be used.  The dryer vibrates
slightly when it runs and this will cause the steam coil
connections to crack if they are hard piped to the supply and
return mains.

Shutoff valves for each dryer should be installed in the supply
line, return line, and drip trap return line.  This will allow the
dryer to be isolated from the supply main and the return main
if the dryer needs maintenance work.

Install an inverted bucket steam trap and check valve at least
12-inches (30.48 cm) below the steam coil as close to the
coil as possible.  A trap with a minimum capacity of 100 lb
(45.35 kg) of condensate per hour at 125 psi (8.62 bar) is
needed for each unit.  (Based on 2 times the steam
consumption per hour.)

The supply line and the return line should be insulated.  This
will save energy and provide for the safety of the operator and
maintenance personnel.

Operating Steam Pressure

 Maximum

125 psig*

861.85 kPa

 Heat Input (Normal Load)

1.2

 

Bhp

 Consumption (Approximate)
 @ 125 psi (8.6 bar)

45

 

lb/hr

20.41 kg/hr

MLG33 Operating Steam Pressure

 Maximum

125 psig*

861.85 kPa

 Heat Input (Normal Load)

1.75

 

Bhp

 Consumption (Approximate)
 @ 125 psi (8.6 bar)

63 lb/hr

28.58 kg/hr

Water pockets in the supply line, caused by low points, will
provide wet steam to the coil possibly causing steam coil
damage.  All horizontal runs of steam supply piping should
be pitched 1/4-inch (6.35 mm) for every 1 foot (0.31 meters)
back towards the steam supply header causing the
condensate in the line to drain to the header.  Install a bypass
trap in any low point to eliminate wet steam.

Important

Flexible hoses/couplings must be used.  Coil
failure due to hard plumbing connections will void

the warranty.

Water Information_____________________

Before You Start

Check Local Codes and Permits

Call your local water company or the proper municipal
authority for information regarding local codes.

Important

It is your responsibility to have all plumbing
connections made by a qualified professional to

ensure that the plumbing installation is adequate and
conforms to local, state, and federal regulations or codes.

It is the installer’s or owner’s responsibility to see that the
required water pressure, pipe size, or connections are
provided.  The manufacturer assumes no responsibility if
the fire suppression system is not connected, installed, or
maintained properly.

Installation

Water Supply

The fire suppression system must be supplied with a
minimum water pipe size of 1/2-inch (12.7 mm) and be
provided with 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) of
pressure.

If the rear area of the dryer or the water supply is located in an
area where it will be exposed to cold/freezing temperatures,
provisions must be made to protect these water lines from
freezing.

Warning

If the water in the supply line or water solenoid
valve freezes, the fire suppression system will be

inoperative!!

Water Connections

The water connection is made to the 3/4”-11.5 NH hose
adaptor, which is shipped in the tumbler and must be installed
to the 1/2” N.P.T. water connection, located at the upper rear
of the dryer.  A flexible supply line/coupling must be used in
an effort to avoid damaging the electric water solenoid valve.

Note

The 3/4”-11.5 NH is a standard hose coupling
screw thread.  It is not to be confused with 3/4”

N.P.T.  The sealing of an NH connection is made with a
washer opposed to the mating threads of an N.P.T.
assembly.  The 2 thread designs are not compatible.

It is recommended that a filter or strainer be installed in the
water supply line.

NOT AVAILABLE

Содержание MLG33PDAWW

Страница 1: ...ent professional AVERTISSEMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel to...

Страница 2: ...__________________________________ MODELNO _________________ DEALER SNAME _________________________________________________________________________________________ Serial Number s ____________________...

Страница 3: ...Personal injury or fire could result The dryer must never be operated without the lint filter screen in place even if an external lint collection system is used FOR YOUR SAFETY Do not dry mop heads in...

Страница 4: ...mage plastics or rubber and also may be a fire hazard A program should be established for the inspection and cleaning of lint in the burner area exhaust ductwork and area around the back of the dryer...

Страница 5: ..._________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ______...

Страница 6: ...ER POCKET 40 000 Btu hr 10 080 kcal hr EXHAUST CONNECTION DIAMETER PER POCKET 4 10 16 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION PER POCKET 3 8 M N P T 3 8 M B S...

Страница 7: ...113413 1 Telephone 641 787 7000 7 Specifications _____________________________________________________________________ NOT AVAILABLE...

Страница 8: ...EAT INPUT PER POCKET 55 000 Btu hr 13 860 kcal hr EXHAUST CONNECTION DIAMETER PER POCKET 6 15 24 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION PER POCKET 3 8 M N P T...

Страница 9: ...113413 1 Telephone 641 787 7000 9 MLG33 Specifications _____________________________________________________________...

Страница 10: ...ed in this manual refer to Exhaust Requirements section Important The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clea...

Страница 11: ...ch results in slow drying increased use of energy and shutdown of the burner by the airflow sail switch burner hi limits or lint chamber hi limit protector thermostat The dryer must be installed with...

Страница 12: ...90 elbows should be used in the exhaust duct run If more than the equivalent of 4 90 elbows are used the cross sectional area of the ductwork must be increased Multiple Dryer Common Venting Important...

Страница 13: ...to make changes in specifications at any time without notice or obligation Important A separate protected circuit must be provided to each pocket The dryer must be connected to the electric supply sh...

Страница 14: ...ct voltage When fuses are used they must be dual element time delay current limiting class RK1 or RK5 ONLY Calculate determine correct fuse value by applying either local and or National Electrical Co...

Страница 15: ...strain relief must be installed where the wiring enters the dryer For CE Models Only The means for disconnection from the supply must be incorporated into wiring having a minimum contact separation o...

Страница 16: ...ning Fire or explosion could result due to failure of isolating or disconnecting the gas supply as noted Note Undersized gas piping will result in ignition problems slow drying increased use of energy...

Страница 17: ...M3 H 36 2 705 1 Butane G30 3 175 28 30 40 000 11 72 0 845 kg H 44 2 184 1 Propane G31 2 500 37 40 000 11 72 0 845 kg H 44 2 184 1 Butane G30 3 175 28 30 50 40 000 11 72 0 845 kg H 39 2 527 1 6 1 Prop...

Страница 18: ..._____________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ __________...

Страница 19: ...e the gas train out of the gas train enclosure The carbon ignitor located at the far end of the gas train is very fragile Remove 2 burner tube mounting screws and remove burner tube in order to gain a...

Страница 20: ...gas train engages into the mounting slot Connect the union and the 3 electrical plugs Repeat these steps for the other burner Open all shutoff valves reconnect electrical power to the dryer and test f...

Страница 21: ...ack of the steam coils Important Coil failure due to improper pH level will void the warranty Gas Pressure Testing__________________ For proper operation the gas pressure must be correct consistent an...

Страница 22: ...am Pressure Maximum 125 psig 861 85 kPa Heat Input Normal Load 1 75 Bhp Consumption Approximate 125 psi 8 6 bar 63 lb hr 28 58 kg hr Water pockets in the supply line caused by low points will provide...

Страница 23: ...tumbler drum by hand to be sure it moves freely Check bolts nuts screws terminals and fittings for tightness and security Check that the vent is connected to the dryer and is exhausted to the outdoor...

Страница 24: ...rt and the L C D will display the Dry Cycle selected and the remaining time The dryer will continue through the drying and cooling cycles until the vended time has expired Note To stop the dryer open...

Страница 25: ...r from whom you purchased the equipment and request a dryer warranty form If the dealer cannot be contacted or is unknown warranty information can be obtained from the Maytag Co Note Whenever contacti...

Страница 26: ...Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area Warning To avoid the hazard of electrical shock discontinue electrical supply to the dryer Steam Dryers...

Страница 27: ...gas electric or steam 2 Serial Number Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular dryer gas either natura...

Страница 28: ...Part No 113413 1 06 02 05 0...

Отзывы: