If multiple units are exhausted into a common duct:

1. An exhaust cross-section area of 82cm

2

(12.6”

2

) is required per dryer. This will allow for free air movement

should all dryers be operated simultaneously.

2. A power exhaust may be used on multiple installations.
3. Ducts larger than 100mm (4”) diameter can result in increased lint accumulation. Such lint accumulation

should be cleaned regularly.

4. Exhaust ducting should be kept as short and direct as possible.

The operating pressure in any exhaust system must not exceed 23mm (0.92”) water gauge, or be less than 0.
This can be measured with the dryer(s) operating, by inserting a manometer connection at the point where
the exhaust duct connects to the dryer (a no-heat setting should be used, without clothes loaded and with a
clean lint filter).

Inspect and clean the interior of the exhaust system at least once a year. Disconnect from the electricity
supply prior to cleaning. Check the gas supply connection any time the dryer is moved. Frequently check to
be sure the exhaust hood flap opens and closes freely.

5. ELECTRICAL CONNECTION

WARNING:

This is a 3-wire appliance which must be earthed.

Note:

Single and stacked pair dryers are intended to be supplied by one electricity supply cord. The elec-

trical connection procedure is the same for both.

Each single and stacked pair gas dryer is fitted with an electrical supply cord and plug. It should be connected
to an electricity supply socket at the voltage shown on the dataplate. The minimum supply fuse capacity
should be 5A for single or 10A for stacked pair dryers. The dryer must be positioned so that the plug is
accessible. If the fitted plug is not used, the electrical connection must be carried out by a competent
electrician in accordance with local or national wiring regulations.

For Australia, each single electric dryer is fitted with a 20A cord and plug, and should be plugged into a suitable
electrical socket at the voltage shown on the dataplate.

Do not use extension lead assemblies on commercial installations.

If the supply cord is damaged, it must be replaced with a specially terminated cord by an authorized service
agent or a similarly qualified person in order to avoid a
hazard.

Each electric dryer for other countries is supplied with-
out an electric cord and plug. They must be connected
to a single-phase electricity supply at the voltage shown
on the dataplate, by a suitable fixed wiring installation in
accordance with local and national wiring regulations. A
switch with a minimum contact separation of 3mm in
both poles must be incorporated into the fixed wiring for
dryer disconnection. A cord clamp bush is provided with
the dryer, and should be tightened on completion of
wiring. The electrical mains terminals are located
behind the small rear access panel, and connections
should be made as shown in the figure. Remember to
replace the terminal access panel.

Electric Single Dryer:

A 3-wire circular cord of

minimum conductor size 2.5mm

2

cross-section area

should be used. A 30A supply fuse should be used.

Electric Dryer/Dryer:

A 3-wire cable of minimum

conductor size 6.0mm

2

cross-section area should be

used. A 60A supply fuse should be used.

2-Wire and Ground System

Neutral

Post

Neutral

Power

Cord

Ground

Wire

Power

cord

and

strain

relief

Содержание MLE23PD

Страница 1: ...G16CS MLG23PD MDE21PN MDE21PD MDE16PD MDE16MN MDE16CS MLE23PD ISTRUZIONI DI INSTALLAZIONE DI ASCIUGA BIANCHERIA COMMERCIALI A GAS ED ELETTRICI MODELLI MDG21PN MDG21PD MDG16PD MDG16MN MDG16CS MLG23PD M...

Страница 2: ...dryers have been certified for operation on either natural gas or LP gas Australia propane only with appropriate conversion Service calls performed as a result of incorrect installation may be the res...

Страница 3: ...s important to allow space around the dryer for adequate ventilation and exhausting The minimum spacing requirements are shown in the figure below 0 cm 0 cm 56 5 cm 22 1 4 1 cm Minimum FRONT VIEW SIDE...

Страница 4: ...d hinges 8 Replace the hinge hole covers and screws in the opposite side For upper dryer of stacked pair see figure below 1 Remove the 2 hole plugs by gently prying out with a screwdriver Pull the doo...

Страница 5: ...y from the dry cleaners The dryer must not be installed or stored in an area where it will be exposed to water and or weather The area must be kept clear and free of combustible materials flammable va...

Страница 6: ...exhaust outlet When possible do not exhaust the dryer directly into a basement window well in order to avoid a lint build up Do not exhaust under a building If exhaust ductwork must run through an un...

Страница 7: ...le or 10A for stacked pair dryers The dryer must be positioned so that the plug is accessible If the fitted plug is not used the electrical connection must be carried out by a competent electrician in...

Страница 8: ...sion to ISO 7 1 thread A 12 5mm 1 2 gas supply line is recommended for each dryer For multiple unit installations the size of the main gas line must be adequate for the number of dryers see Technical...

Страница 9: ...on of the burner mostly blue flame the professional installation engineer may remove the front panel and stacked pair access panel to view the burner WARNING Do not touch any electrical parts and repl...

Страница 10: ...ento con gas natural o gas LP Australia solamente propano con la conversi n apropiada Las llamadas para asistencia t cnica realizadas como resultado de la instalaci n incorrecta pueden ser responsabil...

Страница 11: ...TA LATERAL 0 cm La profundidad total de los modelos altos MN incluyendo los botones de los temporizadores es de 73 7 cm 29 Conexi n al colector de gas 99 5 cm 39 5 32 97 cm 38 3 16 6 2 cm 2 7 16 8 3 c...

Страница 12: ...los en el lado opuesto Para la secadora superior de las secadoras apiladas v ase figura a continuaci n 1 Desmonte los dos tapones de agujeros sac ndolos con cuidado con la ayuda de un destornillador S...

Страница 13: ...ra no debe instalarse o almacenarse en un rea donde est expuesta al agua y o a los agentes atmosf ricos El rea debe mantenerse limpia y sin materiales combustibles ni vapores o l quidos inflamables Pa...

Страница 14: ...bre la salida de ventilaci n Cuando sea posible no ventile la secadora directamente en el hueco de una ventana del s tano a fin de evitar la acumulaci n de pelusa No ventile debajo de un edificio Si e...

Страница 15: ...fusible de su ministro debe ser de 5 A para secadoras solas o 10 A para secadoras en pares apilados La secadora debe colo carse de forma que el enchufe sea accesible Si no se usa el enchufe la conexi...

Страница 16: ...a cada secadora Para instalaciones con unidades m ltiples el tama o de la l nea principal de gas debe ser adecuada para el n mero de secadoras vea la Especificaci n T cnica para el flujo de gas por se...

Страница 17: ...nto correcto del quemador indicada por la llama azul el t cnico profesional de instalaci n puede desmontar el panel frontal y el panel de acceso de las dos secadoras apiladas para ver el quemador ADVE...

Страница 18: ...i certificati per funzionamento sia con gas naturale che con gas LP propano liquido Australia solo propano dopo aver applicato la conversione idonea Le chiamate di servizio dovute ad una installazione...

Страница 19: ...m minimo VISTA FRONTALE VISTA LATERALE 0 cm Profondit totale dei modelli con MN superiore comprese manopole timer 73 3 cm 29 12 7 cm 5 69 cm 27 3 16 69 9 cm 27 1 2 collegamento a collettore gas 104 2...

Страница 20: ...ei fori cerniere sul lato opposto Per asciuga biancheria superiore nella coppia sovrapposta vedi figura sotto 1 Rimuovere i due tappi dai fori spingendoli con dolcezza fuori con un cacciavite Spingere...

Страница 21: ...ancheria non deve essere installato o conservato in luoghi dove rimanga esposto all acqua e o alle condizioni atmosferiche La zona deve essere tenuta pulita e priva di materiali combustibili vapori o...

Страница 22: ...ciuga biancheria diret tamente su incavi di finestre di seminterrati in modo da evitare l accumulo di fibre Non far scaricare sotto ad un edificio Se la tubatura di scarico deve correre attraverso una...

Страница 23: ...e essere posizionato in modo che la spina sia accessibile Se non si usa la spina provvista l allacciamento elettrico deve essere eseguito da un elettricista competente in confor mit con le regolamenta...

Страница 24: ...alimentazione gas da 12 5 mm 1 2 Per installazioni con pi unit la dimensione della linea di gas di rete deve essere adeguata al numero di asciuga biancheria per il flusso di gas per ogni asciuga bian...

Страница 25: ...ta Per confermare che il gas sia accesso e che il bruciatore funzioni correttamente soprattutto fiamma blu il tecnico professionista di installazioni pu togliere il pannello frontale ed il pannello di...

Страница 26: ...YTAG APPLIANCES 1 Dependability Square Newton Iowa 50208 U S A Fabricante MAYTAG APPLIANCES 1 Dependability Square Newton Iowa 50208 EE UU Produttore MAYTAG APPLIANCES 1 Dependability Square Newton Io...

Отзывы: