Connect inlet hoses to water supplies using screen washer at tap connections.

NOTE:

Accessory inlet hoses are available tin various lengths up to 3m (10’).

Ensure the correct hose end is used on each hose. The appliance end has an
NPT thread. The water supply end has a standard European 3/4” BSP thread. Do
not overtighten hose connections. Hand tight should be adequate to avoid leaks
without damaging the sealing washer.

10. Drain hose connection

Install gooseneck end of drain hose into a standpipe. Be sure an air-tight
connection is NOT made between the drain hose and the standpipe.

Recommended height of the standpipe is 0.9m (36”). If the standpipe is less than 0.6m (24”) high, the
drain hose should be routed through the clip to raise the hose to the proper height. Standpipe must be
large enough to accept the outside diameter of the drain hose.

If a floor drain is used, route the drain hose through the drain hose clip before routing to the drain.

Without the 0.6m (24”) high elevation, water may run out of the washer prematurely.

NOTE:

Caution must always be exercised to avoid kinking the drain hose. For best performance the

drain hose should not be restricted in any way, through elbows, couplings or excessive lengths.

CLIP

HOSE

RETAINER

11. Commercial installation accessories

For all accessories and replacement parts, contact your Maytag Commercial Distributor.

– Vent hood – 100mm (4”) opening ...................................................................................................059129

– Aluminum duct pipe – 100mm x 610mm (4” x 24”).........................................................................059130

– Aluminum elbow, 100mm (4”) .........................................................................................................059131

– Aluminum window plate – 381mm x 508mm (15” x 20”) with 100mm (4”) hole .............................059134

– Flexible aluminum duct – 100mm (4”) – 812mm (38”) extending to 2.44m (8’)..............................304353

– Clamp for flexible aluminum duct ....................................................................................................304630

– Exhaust duct kit for base or left side exhausting ........................................................................12001453

– Rectangular vent kit ........................................................................................................................059144

– Anchor bracket kit............................................................................................................................303740

– Gas conversion kit NATURAL to LPG.............................................................................................306195

– Gas conversion kit LPG to NATURAL.............................................................................................306204

– Earthing kit ..................................................................................................................................12001875

To prevent accidental dislodging secure the drain hose to the standpipe, inlet hose or laundry tub with the
tie strap provided in the parts package.

Содержание MLE19PD

Страница 1: ...RIC STACKED WASHER DRYER INSTALLATION INSTRUCTIONS MODELS MLG19PD MLE19PD The installation including a proper exhaust system is the responsibility of the owner LEAVE THESE INSTRUCTIONS WITH THE OWNER...

Страница 2: ...o be carried out in accordance with the AGA Installation Code for gas burning appliances Maytag gas dryers have been certified for operation on either Natural Gas or LP Gas with appropriate conversion...

Страница 3: ...stalling the dryer the following minimum clearances to combustibles apply clearance to wall and sides 0 inches Top 0 inches with outside exhaust rear 0 inches with outside exhaust It is important to m...

Страница 4: ...e by removing the two wire hooks with a screwdriver as shown Locate the metal buckles attached to the shipping straps at back of washer Carefully cut away straps near both buckles completely removing...

Страница 5: ...PLASTIC OR NON METAL FLEXIBLE DUCT If your existing ductwork is plastic non metal or combustible replace it with metal Plastic flexible duct can kink sag be punctured reduce airflow extend drying tim...

Страница 6: ...the dryer a no heat part of a cycle should be used without clothes load and with a clean lint filter Inspect and clean the interior of the dryer exhaust system at least twice a year Disconnect from th...

Страница 7: ...r Gas connection to the dryer must be made by means of a flexible gas hose suitable for the appliance and gas category a fixed gas pipe could be damaged should the machine vibrate A means of restraint...

Страница 8: ...in hose clip before routing to the drain Without the 0 6m 24 high elevation water may run out of the washer prematurely NOTE Caution must always be exercised to avoid kinking the drain hose For best p...

Страница 9: ...check the operation of the dryer first then the washer Dryer On gas dryers the burner may not ignite initially due to air in the gas pipework Allowing the dryer to operate on a heat setting will purg...

Страница 10: ...ssure normal 29 mb 2 9 KPa Test point pressure Not applicable LP gas propane G31 Gas rate 0 246 m3 h 23 6 MJ h Injector size 1 25mm Supply pressure normal 37 mb 3 7 KPa Test point pressure Not applica...

Отзывы: