The exhaust duct should end with an exhaust hood with a swing-out flap to prevent back-draughts and
access for wildlife 

(see 

Accessories

)

. Never use an exhaust hood with a magnetic flap. The hood

should have at least 300mm (12”) clearance between the bottom of the hood and the ground or other
obstruction. The hood opening should point down. Never install a screen over the exhaust outlet.

When possible, do not exhaust the dryer directly into a basement window well in order to avoid a lint
build-up. Do not exhaust under a building. If exhaust ductwork must run through an unheated area, the
duct should be insulated and slope slightly down towards the exhaust hood to reduce condensation and
lint build-up.

If an existing exhaust system is to be used with your new machine, you must ensure:

– The exhaust system meets all local and national regulations
– That plastic flexible duct is not used.
– To completely inspect and clean all lint accumulation from the duct interior.
– The duct is not kinked or crushed which could restrict airflow.
– The exhaust hood flap opens and closes freely.

If multiple units are exhausted into a common duct:

1. An exhaust cross-section area of 78cm

2

(12.6”

2

) is required per dryer. This will allow for free air

movement should all dryers be operated simultaneously.

2. A power exhaust may be used on multiple installations.
3. Ducts larger than 100mm (4”) diameter can result in increased lint accumulation. Such lint

accumulation should be cleaned regularly.

4. Exhaust ducting should be kept as short and direct as possible.

The operating pressure in the exhaust system must not exceed 23mm (0.92”) water gauge, or be less
than 0. This can be measured with the dryer(s) operating, by inserting a manometer connection at the
point where the exhaust duct connects to the dryer (a no-heat part of a cycle should be used, without
clothes load and with a clean lint filter).

Inspect and clean the interior of the dryer exhaust system at least twice a year. Disconnect from the
electricity supply prior to cleaning. Check the gas supply connection any time the machine is moved.
Frequently check to be sure the exhaust hood flap opens and closes freely.

7. Electrical connection

WARNING:

This is a 3-wire appliance which must be earthed.

The gas dryer/washer is fitted with an electrical supply cord and plug. It
should be connected to an electricity supply socket at the voltage shown
on the dataplate. The minimum supply fuse capacity should be 10A. The
appliance must be positioned so that the plug is accessible. If the fitted
plug is not used, the electrical connection must be carried out by a com-
petent electrician in accordance with local or national wiring regulations.

Do not use extension lead assemblies on commercial installations.

If the supply cord is damaged, it must be replaced with a specially
terminated cord by an authorized service agent or a similarly qualified
person in order to avoid a hazard.

The electric dryer/washer is supplied without an electric cord and plug. It must be connected to a single-
phase electricity supply at the voltage shown on the dataplate, by a suitable fixed wiring installation in
accordance with local and national wiring regulations. A 3-wire circular cord of minimum conductor size
2.5mm

2

cross-section area should be used. A 30A supply fuse should be used, and a switch with a

minimum contact separation of 3mm in both poles must be incorporated into the fixed wiring for machine
disconnection. A cord clamp bush is provided with the machine, and should be tightened on completion
of wiring. The electrical mains terminals are located behind the small rear access panel at the top of the
dryer, and connections should be made as shown in the figure above. Remember to replace the terminal
access panel.

Содержание MLE19PD

Страница 1: ...RIC STACKED WASHER DRYER INSTALLATION INSTRUCTIONS MODELS MLG19PD MLE19PD The installation including a proper exhaust system is the responsibility of the owner LEAVE THESE INSTRUCTIONS WITH THE OWNER...

Страница 2: ...o be carried out in accordance with the AGA Installation Code for gas burning appliances Maytag gas dryers have been certified for operation on either Natural Gas or LP Gas with appropriate conversion...

Страница 3: ...stalling the dryer the following minimum clearances to combustibles apply clearance to wall and sides 0 inches Top 0 inches with outside exhaust rear 0 inches with outside exhaust It is important to m...

Страница 4: ...e by removing the two wire hooks with a screwdriver as shown Locate the metal buckles attached to the shipping straps at back of washer Carefully cut away straps near both buckles completely removing...

Страница 5: ...PLASTIC OR NON METAL FLEXIBLE DUCT If your existing ductwork is plastic non metal or combustible replace it with metal Plastic flexible duct can kink sag be punctured reduce airflow extend drying tim...

Страница 6: ...the dryer a no heat part of a cycle should be used without clothes load and with a clean lint filter Inspect and clean the interior of the dryer exhaust system at least twice a year Disconnect from th...

Страница 7: ...r Gas connection to the dryer must be made by means of a flexible gas hose suitable for the appliance and gas category a fixed gas pipe could be damaged should the machine vibrate A means of restraint...

Страница 8: ...in hose clip before routing to the drain Without the 0 6m 24 high elevation water may run out of the washer prematurely NOTE Caution must always be exercised to avoid kinking the drain hose For best p...

Страница 9: ...check the operation of the dryer first then the washer Dryer On gas dryers the burner may not ignite initially due to air in the gas pipework Allowing the dryer to operate on a heat setting will purg...

Страница 10: ...ssure normal 29 mb 2 9 KPa Test point pressure Not applicable LP gas propane G31 Gas rate 0 246 m3 h 23 6 MJ h Injector size 1 25mm Supply pressure normal 37 mb 3 7 KPa Test point pressure Not applica...

Отзывы: