NOTE:

In accordance with the European EMC Directive (89/336/EEC) the maximum

electricity supply system impedance to which the electric dryer/washer should be
connected is declared to be 0.247

+ J0.155

.

Some local wiring regulations require connection of an additional earth bond
connection to the appliance. An earthing kit (Part No. 12001875) is available.
It contains the earth wire, clamp, earth screw and washer. The wire should be
connected to the earth (ground) terminal on the rear panel of the dryer using the
additional screw and washer shown at right.

8. Gas connection

WARNING:

The gas dryer is factory-set with a burner orifice for Natural Gas supply

(see 

Technical Specification

)

. It may be converted for use with LP (butane or

propane) gas using the correct conversion kit 

(see 

Accessories

)

. Full instructions

are supplied with the kit. Before installation, check that the local distribution
conditions, nature of gas and pressure, and the adjustment of the appliance are
compatible.

Gas installation must be carried out in accordance with any local or national gas
installation regulations by a suitably qualified person.

Each dryer gas inlet connection is 3/8” NPT thread. An adapter is included for
conversion to ISO.7-1 thread. A 12.5mm (1/2”) gas supply line is recommended for
each dryer. For multiple unit installations the size of the main gas line must be
adequate for the number of dryers 

(see 

Technical Specification 

for gas flow rate

per dryer)

.

Gas connection to the dryer must be made by means of a flexible gas hose suitable for the appliance
and gas category (a fixed gas pipe could be damaged should the machine vibrate). A means of restraint
should be used on the appliance to prevent straining of the gas supply when the appliance is moved.

Remove the gas inlet connection thread protective cap. Apply jointing compound or approximately 1-1/2
turns of PTFE sealing tape over all threaded connections, and securely tighten (Note: jointing compound
used must be resistant to LPG).

Check for leaks as directed by local or national regulations.

DO NOT

use a naked flame to check for gas

leaks. A pressure measurement tapping is provided on the gas valve within each dryer, accessible after
removal of the front service access panel (disconnect from electricity supply before removing this panel).

NOTE:

All gas dryers should be disconnected from gas supply before any over-pressure testing of the

gas supply system.

The gas dryer uses an automatic ignition system to ignite the burner.

There is no constant burning

pilot light.

9. Water supply connection

Cold water supply:

Pressure:

0.2 – 0.8 MPa (30 – 120 p.s.i.)

Temperature:

25°C max. (77°F max.)

Hot water supply:

Pressure:

0.2 – 0.8 MPa (30 – 120 p.s.i.)

Temperature:

49°C – 60°C (120°F – 140°F)

These water pressures are required to correctly fill the washer in the proper time. Pressures of less than
0.2 MPa may cause a malfunction in the machine water valve, and it may also not shut off completely.

Fit water supply stop-taps to allow easy disconnection of fill hoses. Always turn taps off when washer is
not in use (make sure they are accessible).

EARTH BOND

SCREW

(GROUND)

Содержание MLE19PD

Страница 1: ...RIC STACKED WASHER DRYER INSTALLATION INSTRUCTIONS MODELS MLG19PD MLE19PD The installation including a proper exhaust system is the responsibility of the owner LEAVE THESE INSTRUCTIONS WITH THE OWNER...

Страница 2: ...o be carried out in accordance with the AGA Installation Code for gas burning appliances Maytag gas dryers have been certified for operation on either Natural Gas or LP Gas with appropriate conversion...

Страница 3: ...stalling the dryer the following minimum clearances to combustibles apply clearance to wall and sides 0 inches Top 0 inches with outside exhaust rear 0 inches with outside exhaust It is important to m...

Страница 4: ...e by removing the two wire hooks with a screwdriver as shown Locate the metal buckles attached to the shipping straps at back of washer Carefully cut away straps near both buckles completely removing...

Страница 5: ...PLASTIC OR NON METAL FLEXIBLE DUCT If your existing ductwork is plastic non metal or combustible replace it with metal Plastic flexible duct can kink sag be punctured reduce airflow extend drying tim...

Страница 6: ...the dryer a no heat part of a cycle should be used without clothes load and with a clean lint filter Inspect and clean the interior of the dryer exhaust system at least twice a year Disconnect from th...

Страница 7: ...r Gas connection to the dryer must be made by means of a flexible gas hose suitable for the appliance and gas category a fixed gas pipe could be damaged should the machine vibrate A means of restraint...

Страница 8: ...in hose clip before routing to the drain Without the 0 6m 24 high elevation water may run out of the washer prematurely NOTE Caution must always be exercised to avoid kinking the drain hose For best p...

Страница 9: ...check the operation of the dryer first then the washer Dryer On gas dryers the burner may not ignite initially due to air in the gas pipework Allowing the dryer to operate on a heat setting will purg...

Страница 10: ...ssure normal 29 mb 2 9 KPa Test point pressure Not applicable LP gas propane G31 Gas rate 0 246 m3 h 23 6 MJ h Injector size 1 25mm Supply pressure normal 37 mb 3 7 KPa Test point pressure Not applica...

Отзывы: