Maytag MGDB850WL - 29

4

INSTALLATION REQUIREMENTS

Tools an

d

 Parts

Gather the required tools and parts before starting installation. Read 
and follow the instructions provided with any tools listed here. 

Flat-blade screwdriver

Adjustable wrench that 
opens to 1" (25 mm) or 

 

hex-head socket wrench 

 

(for adjusting dryer feet)

Level

Vent clamps

Knife

Caulking gun and compound 
(for installing new exhaust 
vent)

Tin snips (new vent 
installations)

1/4" nut driver 
(recommended)

Tape measure

Pliers

For All Installations:

Gas Installations:

8" or 10" pipe wrench

8" or 10" adjustable wrench 
(for gas connections)

Pipe-joint compound 
resistant to LP gas

Parts supplie

d

Non-Steam Mo

d

els

4 Leveling legs

Steam Mo

d

els

A

B

C

D

E

A. Leveling legs (4)
B. “Y” connector

C. Short inlet hose

D. Inlet hose with right-angle 

connector

E. Rubber washer

Remove parts package from dryer drum. Check that all parts 

 

are included.

NOTE:

 Do not use leveling legs supplied with dryer if installing 

 

on a pedestal.

Parts nee

d

e

d

Check local codes. Check existing electrical supply and venting. 
See “Electrical Requirements” and “Venting Requirements” before 
purchasing parts.

Mobile home installations require metal exhaust system hardware 
available for purchase from the dealer from whom you purchased 
your dryer. For further information, please refer to the “Assistance 

 

or Service” section in your Use and Care Guide.

Optional Equipment

Refer to your Use and Care guide for information about the 
accessories available for your dryer.

Location Requirements 

You will nee

d

A location that allows for proper exhaust installation. 

 

See “Venting Requirements.”

A separate 30-amp circuit.

If you are using a power supply cord, a grounded electrical 
outlet located within 2 ft. (610 mm) of either side of the dryer. 

 

See “Electrical Requirements.”

A sturdy floor to support the total dryer weight of 200 lbs 

 

(90.7 kg). The combined weight of a companion appliance 
should also be considered.

A level floor with a maximum slope of 1" (25 mm) under entire 
dryer. If slope is greater than 1" (25 mm), install Extended Dryer 
Feet Kit, Part Number 279810. Clothes may not tumble properly 
and automatic sensor cycles may not operate correctly if dryer 

 

is not level.

For a garage installation, you will need to place the dryer at least 
18" (460 mm) above the floor. If using a pedestal, you will need 
18" (460 mm) to the bottom of the dryer.

Steam models only: Cold water faucets located within 

 

4 ft. (1.2 m) of dryer, and water pressure of 20-100 psi 

 

(137.9-689.6 kPa). Cold water supply may come from 

 

washer using “Y” connector provided.

Do not operate your dryer at temperatures below 45ºF (7ºC). 

 

At lower temperatures, the dryer might not shut off at the end 

 

of an automatic sensor cycle. This can result in longer drying times.

The dryer must not be installed or stored in an area where it will 

 

be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, 

 

or sleeping quarters. Contact your local building inspector.

Содержание MGDB850WL - 29" Gas Dryer

Страница 1: ...TION 12 REVERSE DOOR SWING 12 TROUBLESHOOTING 14 Dryer Operation 14 Dryer Results 15 TABLE DES MATI RES S CURIT DE LA S CHEUSE 16 EXIGENCES D INSTALLATION 18 Outillage et pi ces 18 quipement facultati...

Страница 2: ...nstructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safet...

Страница 3: ...e detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smel...

Страница 4: ...de for information about the accessories available for your dryer Location Requirements You will need A location that allows for proper exhaust installation See Venting Requirements A separate 30 amp...

Страница 5: ...bottom of the door are required Louvered doors with equivalent ventilation openings are acceptable Companion appliance spacing should also be considered 14 m x 356 mm 29 737 mm 5 127 mm 1 25 mm 1 25 m...

Страница 6: ...within reach of dryer s final location 4 wire receptacle 14 30R If using a replacement power supply cord it is recommended that you use Power Supply Cord Replacement Part Number 9831317 For further i...

Страница 7: ...if local codes and gas supplier permit If you are using Natural gas do not use copper tubing Lengths over 20 ft 6 1 m should use larger tubing and a different size adapter fitting If your dryer has be...

Страница 8: ...nt according to the supply line type size and location A 3 8 flexible gas connector B 3 8 dryer pipe C 3 8 to 3 8 pipe elbow D 3 8 pipe to flare adapter fitting A B C D 3 Open the shutoff valve in the...

Страница 9: ...Good Better Clamps Use clamps to seal all joints Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct and catch lint Do not u...

Страница 10: ...st vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home Terminate the exhaust vent outside Determine vent path Select...

Страница 11: ...re the vent is clean The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood Check that the vent is secured to exhaust hood with a 4 102 mm clamp 2 Move dryer into its final...

Страница 12: ...blue film on the console and any tape remaining on the dryer 7 Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust 8 Read the Dryer Use section in your Use and Care Guide Ele...

Страница 13: ...om the dryer door opening 2 Remove the cosmetic screw opposite the door strike A B A Door strike B Cosmetic screw 3 Reinstall the door strike and cosmetic screw on the opposite side of dryer door open...

Страница 14: ...use No heat Has a household fuse blown or has a circuit breaker tripped The drum may be turning but you may not have heat Electric dryers use 2 household fuses or circuit breakers Replace the fuse or...

Страница 15: ...l or flexible metal vent See the Installation Instructions Are fabric softener sheets blocking the grille Use only one fabric softener sheet and use it only once Is the exhaust vent the correct length...

Страница 16: ...de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous...

Страница 17: ...d installation B149 1 du gaz naturel ou du propane La s cheuse doit tre lectriquement reli e la terre conform ment aux codes locaux ou en l absence de codes locaux au Code canadien de l lectricit CSA...

Страница 18: ...ent un syst me d vacuation en m tal disponible chez le marchand chez qui vous avez achet votre s cheuse Pour en savoir plus veuillez consulter la section Assistance ou service de votre Guide d utilisa...

Страница 19: ...entaire peut tre requis pour les moulures de porte et de plancher et pour les plinthes Un espace suppl mentaire doit tre envisag de tous les c t s de la s cheuse afin de r duire le transfert de bruit...

Страница 20: ...14 30R En cas d utilisation d un cordon d alimentation de rechange il est recommand d utiliser le cordon d alimentation lectrique num ro 9831317 pi ce de rechange Pour en savoir plus veuillez vous rep...

Страница 21: ...tion en gaz de la s cheuse voir l illustration suivante Un tuyau IPS de 1 2 est recommand Pour les longueurs inf rieures 20 pi 6 1 m on peut utiliser des tuyaux approuv s de cuivre ou d aluminium de 3...

Страница 22: ...ne cl pour serrer raccorder l alimentation en gaz la s cheuse Utiliser un compos d tanch it des tuyauteries sur tous les filetages m les non vas s Si on utilise un conduit m tallique souple veiller ce...

Страница 23: ...d vacuation aupr s du marchand ou en t l phonant Whirlpool Service Pour plus de renseignements voir la section Assistance ou service dans le Guide d utilisation et d entretien Conduit m tallique rigi...

Страница 24: ...pour raccorder les coudes H Bouche de d charge Installations d vacuation facultatives Trousse de recouvrage pour les orifices d vacuation pour les orifices d vacuation mon utilis Pi ce num ro W101865...

Страница 25: ...uation qui vous aideront atteindre la meilleure performance de s chage Tableau des syst mes d vacuation REMARQUE Les conduits d vacuation par le c t et par le bas comportent un changement de direction...

Страница 26: ...inet d eau froide l aide des nouveaux tuyaux d alimentation Ne pas utiliser de tuyaux usag s 1 Arr ter le robinet d eau froide et retirer le tuyau d alimentation de la laveuse 2 Retirer l ancienne ron...

Страница 27: ...V rifier que la s cheuse est d aplomb Voir R glage 6 de l aplomb de la s cheuse 7 Retirer la pellicule de bleue ou tout ruban adh sif rest sur la s cheuse 8 Essuyer soigneusement l int rieur du tambou...

Страница 28: ...se 5 Retirer les quatre chevilles de plastique situ es l ext rieur de l ouverture de la porte de la s cheuse 6 Installer 4 chevilles de plastique dans les trous des vis sur la gauche de la s cheuse ap...

Страница 29: ...e de 240 V V rifier avec un lectricien qualifi A t on utilis un fusible ordinaire Utiliser un fusible temporis Absence de chaleur Un fusible est il grill ou un disjoncteur s est il d clench Le tambour...

Страница 30: ...al lourd ou flexible Voir Instructions d installation Des feuilles d assouplissant de tissu bloquent elles la grille de sortie Utiliser une seule feuille d assouplissant par charge et l utiliser une s...

Страница 31: ...31 NOTES...

Страница 32: ...W10261614A W10267631A SP 2009 Whirlpool Corporation All rights reserved 11 09 Printed in U S A...

Отзывы: