Maytag MGDB850WL - 29

11

Install Vent System

1.

Install exhaust hood. Use caulking compound to seal exterior wall 
opening around exhaust hood.

2.

Connect vent to exhaust hood. Vent must fit inside exhaust hood. 
Secure vent to exhaust hood with 4" (102 mm) clamp.

3.

Run vent to dryer location. Use the straightest path possible. See 
“Determine vent path” in “Plan Vent System.” Avoid 90º turns. 
Use clamps to seal all joints. Do not use duct tape, screws, 

 

or other fastening devices that extend into the interior of the vent 
to secure vent, which can catch lint.

INSTALL LEVELING LEGS

WARNING

Excessive Wei

g

ht Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

1.

To avoid damaging the floor, use a large flat piece of cardboard 
from the dryer carton. Place cardboard under the entire back 
edge of the dryer. 

2.

Firmly grasp the body of the dryer (not the console panel). 

 

Gently lay the dryer on the cardboard. See illustration. 

3.

Examine the leveling legs. Find the diamond marking. 

4.

Screw the legs into the leg holes by hand. Use a wrench to finish 
turning the legs until the diamond marking is no longer visible.

5.

Place a carton corner post from dryer packaging under each 

 

of the 2 dryer back corners. Stand the dryer up. Slide the dryer 

 

on the corner posts until it is close to its final location. Leave 
enough room to connect the exhaust vent.

CONNECT VENT

1.

Using a 4" (102 mm) clamp, connect vent to exhaust outlet 

 

in dryer. If connecting to existing vent, make sure the vent is clean. 
The dryer vent must fit over the dryer exhaust outlet and inside 

 

the exhaust hood. Check that the vent is secured to exhaust hood 
with a 4" (102 mm) clamp.

2.

Move dryer into its final location. Do not crush or kink vent.

3.

(On gas models) Check that there are no kinks in the flexible 

 

gas line.

4.

Once the exhaust vent connection is made, remove the corner 
posts and cardboard.

CONNECT INLET HOSE 

(STEAM MODELS)

The dryer must be connected to the cold water faucet using the new 
inlet hoses. Do not use old hoses.

1.

Turn cold water faucet off and remove washer inlet hose.

2.

Remove old rubber washer from inlet hose and replace with new 
rubber washer provided. If space permits, attach the brass female 
end of the “Y” connector to the cold water faucet.

NOTE:

 If “Y” connector can be attached directly to cold water 

faucet, go to Step 6. If “Y” connector cannot be attached 
directly to the cold water faucet, the short hose must be used. 
Continue with Step 3.

3.

Attach short hose to cold water faucet. Screw on coupling 

 

by hand until it is seated on faucet. 

4.

Using pliers, tighten the couplings with an additional two-thirds 
turn. 

NOTE:

 Do not overtighten. Damage to the coupling can result.

5.

Attach “Y” connector to brass male end of small hose. Screw 

 

on coupling by hand until it is seated on connector.

6.

One end of the long hose has a wire mesh strainer inside 

 

the coupling. Attach this end to the “Y” connector.

7.

Attach washer cold inlet hose to other end of “Y” connector.  
Screw on coupling by hand until it is seated on connector.

A

 

A. Inlet to cold water

8.

Using pliers, tighten the couplings an additional two-thirds turn.

NOTE:

 Do not overtighten. Damage to the coupling can result.

Содержание MGDB850WL - 29" Gas Dryer

Страница 1: ...TION 12 REVERSE DOOR SWING 12 TROUBLESHOOTING 14 Dryer Operation 14 Dryer Results 15 TABLE DES MATI RES S CURIT DE LA S CHEUSE 16 EXIGENCES D INSTALLATION 18 Outillage et pi ces 18 quipement facultati...

Страница 2: ...nstructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safet...

Страница 3: ...e detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smel...

Страница 4: ...de for information about the accessories available for your dryer Location Requirements You will need A location that allows for proper exhaust installation See Venting Requirements A separate 30 amp...

Страница 5: ...bottom of the door are required Louvered doors with equivalent ventilation openings are acceptable Companion appliance spacing should also be considered 14 m x 356 mm 29 737 mm 5 127 mm 1 25 mm 1 25 m...

Страница 6: ...within reach of dryer s final location 4 wire receptacle 14 30R If using a replacement power supply cord it is recommended that you use Power Supply Cord Replacement Part Number 9831317 For further i...

Страница 7: ...if local codes and gas supplier permit If you are using Natural gas do not use copper tubing Lengths over 20 ft 6 1 m should use larger tubing and a different size adapter fitting If your dryer has be...

Страница 8: ...nt according to the supply line type size and location A 3 8 flexible gas connector B 3 8 dryer pipe C 3 8 to 3 8 pipe elbow D 3 8 pipe to flare adapter fitting A B C D 3 Open the shutoff valve in the...

Страница 9: ...Good Better Clamps Use clamps to seal all joints Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct and catch lint Do not u...

Страница 10: ...st vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home Terminate the exhaust vent outside Determine vent path Select...

Страница 11: ...re the vent is clean The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood Check that the vent is secured to exhaust hood with a 4 102 mm clamp 2 Move dryer into its final...

Страница 12: ...blue film on the console and any tape remaining on the dryer 7 Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust 8 Read the Dryer Use section in your Use and Care Guide Ele...

Страница 13: ...om the dryer door opening 2 Remove the cosmetic screw opposite the door strike A B A Door strike B Cosmetic screw 3 Reinstall the door strike and cosmetic screw on the opposite side of dryer door open...

Страница 14: ...use No heat Has a household fuse blown or has a circuit breaker tripped The drum may be turning but you may not have heat Electric dryers use 2 household fuses or circuit breakers Replace the fuse or...

Страница 15: ...l or flexible metal vent See the Installation Instructions Are fabric softener sheets blocking the grille Use only one fabric softener sheet and use it only once Is the exhaust vent the correct length...

Страница 16: ...de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous...

Страница 17: ...d installation B149 1 du gaz naturel ou du propane La s cheuse doit tre lectriquement reli e la terre conform ment aux codes locaux ou en l absence de codes locaux au Code canadien de l lectricit CSA...

Страница 18: ...ent un syst me d vacuation en m tal disponible chez le marchand chez qui vous avez achet votre s cheuse Pour en savoir plus veuillez consulter la section Assistance ou service de votre Guide d utilisa...

Страница 19: ...entaire peut tre requis pour les moulures de porte et de plancher et pour les plinthes Un espace suppl mentaire doit tre envisag de tous les c t s de la s cheuse afin de r duire le transfert de bruit...

Страница 20: ...14 30R En cas d utilisation d un cordon d alimentation de rechange il est recommand d utiliser le cordon d alimentation lectrique num ro 9831317 pi ce de rechange Pour en savoir plus veuillez vous rep...

Страница 21: ...tion en gaz de la s cheuse voir l illustration suivante Un tuyau IPS de 1 2 est recommand Pour les longueurs inf rieures 20 pi 6 1 m on peut utiliser des tuyaux approuv s de cuivre ou d aluminium de 3...

Страница 22: ...ne cl pour serrer raccorder l alimentation en gaz la s cheuse Utiliser un compos d tanch it des tuyauteries sur tous les filetages m les non vas s Si on utilise un conduit m tallique souple veiller ce...

Страница 23: ...d vacuation aupr s du marchand ou en t l phonant Whirlpool Service Pour plus de renseignements voir la section Assistance ou service dans le Guide d utilisation et d entretien Conduit m tallique rigi...

Страница 24: ...pour raccorder les coudes H Bouche de d charge Installations d vacuation facultatives Trousse de recouvrage pour les orifices d vacuation pour les orifices d vacuation mon utilis Pi ce num ro W101865...

Страница 25: ...uation qui vous aideront atteindre la meilleure performance de s chage Tableau des syst mes d vacuation REMARQUE Les conduits d vacuation par le c t et par le bas comportent un changement de direction...

Страница 26: ...inet d eau froide l aide des nouveaux tuyaux d alimentation Ne pas utiliser de tuyaux usag s 1 Arr ter le robinet d eau froide et retirer le tuyau d alimentation de la laveuse 2 Retirer l ancienne ron...

Страница 27: ...V rifier que la s cheuse est d aplomb Voir R glage 6 de l aplomb de la s cheuse 7 Retirer la pellicule de bleue ou tout ruban adh sif rest sur la s cheuse 8 Essuyer soigneusement l int rieur du tambou...

Страница 28: ...se 5 Retirer les quatre chevilles de plastique situ es l ext rieur de l ouverture de la porte de la s cheuse 6 Installer 4 chevilles de plastique dans les trous des vis sur la gauche de la s cheuse ap...

Страница 29: ...e de 240 V V rifier avec un lectricien qualifi A t on utilis un fusible ordinaire Utiliser un fusible temporis Absence de chaleur Un fusible est il grill ou un disjoncteur s est il d clench Le tambour...

Страница 30: ...al lourd ou flexible Voir Instructions d installation Des feuilles d assouplissant de tissu bloquent elles la grille de sortie Utiliser une seule feuille d assouplissant par charge et l utiliser une s...

Страница 31: ...31 NOTES...

Страница 32: ...W10261614A W10267631A SP 2009 Whirlpool Corporation All rights reserved 11 09 Printed in U S A...