9

DRYER GAS PIPE

 

The gas pipe that comes out through the rear of your dryer 
has a 3/8" male pipe thread.

3/8" NPT dryer pipe

NOTE:

 For a garage installation, the gas pipe height must be an 

additional 18" (460 mm) from the floor.

INSTALL LEVELING LEGS

Prepare dryer for leveling legs

1. 

Firmly grasp dryer body (not console panel) and gently lay dryer 

down on back cardboard corner posts.

IMPORTANT:

 If laying dryer on its back, use the cardboard 

corner posts the dryer was packed with to avoid damaging the 
back of the dryer.

Screw in leveling legs

2. 

Using a wrench and tape measure, screw leveling legs into leg 

holes until bottom of foot is approximately 1" (25 mm) from 
bottom of dryer.

Now stand the dryer on its feet. Slide the dryer until it is close 

to its final location. Leave enough room to connect the exhaust 
vent.

For mobile home use

Gas dryers must be securely fastened to the floor.

Mobile home installations require a Mobile

Home Installation Hold-down Kit. For 
ordering information please reference 
the “Quick Reference Guide.”

MAKE ELECTRICAL CONNECTION - 
U.S.A. ONLY

ELECTRICAL CONNECTION

Power Supply Cord

WARNING

Fire Hazard

Use a new UL listed 30 amp power supply cord.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center 
terminal (silver).

Ground wire (green or bare wire) must be connected to 
green ground connector.

Connect remaining 2 supply wires to remaining 
2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or 
electrical shock.

Electrical Connection Options

1.

 

Choose electrical connection type

Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to Power Supply Cord Connection.

3-wire direct connection:
Go to Direct Wire Connection.

4-wire direct connection:
Go to Direct Wire Connection.

Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to Power Supply Cord Connection.

NOTE:

 If local codes do not permit connection of a 

cabinet-ground conductor to neutral wire, go to “Optional 
3-wire connection.” This connection may be used with 
either a power supply cord or a direct wire connection.

Содержание MGD7230HC0

Страница 1: ...nt de l alimentation en gaz 36 Sp cifications de l alimentation du br leur 36 Canalisation de gaz de la s cheuse 36 INSTALLATION DES PIEDS DE NIVELLEMENT 36 EFFECTUER LE RACCORDEMENT LECTRIQUE U SEULE...

Страница 2: ...essages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DAN...

Страница 3: ...d repairs must be performed by a qualified or licensed contractor plumber or gas fitter qualified or licensed by the State of Massachusetts Acceptable Shut off Devices Gas Cocks and Ball Valves instal...

Страница 4: ...ts needed steam models Y connector Short inlet hose Rubber washer 4 Inlet hose If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should cont...

Страница 5: ...s of dryer to reduce noise transfer If a closet door or louvered door is installed top and bottom air openings in door are required Check code requirements Some codes limit or do not permit installati...

Страница 6: ...the dryer cabinet is isolated from the neutral conductor If local codes do not permit the connection of a neutral ground wire to the neutral wire see Optional 3 wire connection section A 4 wire power...

Страница 7: ...d in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or servic...

Страница 8: ...aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing Lengths over 20 ft 6 1 m should use l...

Страница 9: ...ng information please reference the Quick Reference Guide MAKE ELECTRICAL CONNECTION U S A ONLY ELECTRICAL CONNECTION Power Supply Cord WARNING Fire Hazard Use a new UL listed 30 amp power supply cord...

Страница 10: ...upply cord is inside the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Do not further tighten strain relief screws at this point If you...

Страница 11: ...al block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 3 wire Power Supply Cord Conn...

Страница 12: ...ion of the strain relief C through the hole below the terminal block opening B Reaching inside the terminal block opening screw the removable conduit connector A onto the strain relief threads 2 Attac...

Страница 13: ...ce hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tighten screws Finally reinsert tab of terminal block cover in...

Страница 14: ...ing method is acceptable before connecting 1 Prepare to connect neutral ground wire and neutral wire B A E Remove center terminal block screw B Remove neutral ground wire E from external ground conduc...

Страница 15: ...t compound on threads of all non flared male fittings If flexible metal tubing is used be sure there are no kinks NOTE For propane gas connections you must use pipe joint compound resistant to action...

Страница 16: ...ce Do not install in enclosed walls ceilings or floors The total length should not exceed 73 4 ft 2 4 m The length of flexible metal vent used must be included in the overall vent system design as sho...

Страница 17: ...ute that will provide straightest and most direct path outdoors Plan installation to use fewest number of elbows and turns When using elbows or making turns allow as much room as possible Bend vent gr...

Страница 18: ...replace rubber washer Turn cold water faucet off and remove washer inlet hose Remove old rubber washer from inlet hose and replace with new rubber washer 2 Attach short hose and Y connector Attach 2 f...

Страница 19: ...an result Turn on cold water faucet 6 Check that the water faucet is turned on Check for leaks 7 Check for leaks around Y connector faucets and hoses CONNECT VENT 1 Connect vent to exhaust outlet Usin...

Страница 20: ...st leveling legs 2 If dryer is not level prop up using a wood block Use wrench to adjust legs up or down and check again for levelness Locating Pins Locking Features Base trim on some models 3 Place t...

Страница 21: ...utton has been pushed firmly Dryer is plugged into an outlet and or electrical supply is connected Household fuse is intact and tight or circuit breaker has not tripped Dryer door is closed This dryer...

Страница 22: ...panel of dryer Set the hinge screws off to the side for reinstalling the door A B A B 3 Remove the dryer door by lifting upward and out to lift the door off the cabinet Lay the door on a flat covered...

Страница 23: ...2 Remove the 10 screws from the dryer door and setscrews off to the side 3 Remove the inner door by using a plastic putty knife to separate the sides and bottom of the dryer door and trim There are 2...

Страница 24: ...strike plug 6 Remove the door hinges and set off to the side 7 Remove the 3 screws down the left and right sides of the door to remove the outer trim pieces 8 Lift door up and rotate trim pieces to t...

Страница 25: ...ce with the hinges lined up with the hinge holes 11 Install 6 hinge screws and the other 4 screws 12 Install hinge covers and plugs Hinge covers will go inside ways to then rotate 90 and snap into pla...

Страница 26: ...ryer A screen blocked by lint can increase drying time To clean Style 1 1 Pull the lint screen straight up and out Press tab down on front and open lint screen Roll lint off the screen with your finge...

Страница 27: ...See Installation Instructions The venting system attached to the dryer plays a big role in good air flow Blocked or crushed vents as well as improper venting installation will reduce air flow and drye...

Страница 28: ...se trim before moving dryer See Base trim WARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electr...

Страница 29: ...NOTES W11268643B 2020 All rights reserved Tous droits r serv s Todos los derechos reservados 03 20...

Отзывы: