ELECTRICAL REQUIREMENTS -  
U.S.A. ONLY 

It is your responsibility:

 

To contact a qualified electrical installer.

 

To be sure that the electrical connection is adequate and in 
conformance with the National Electrical Code,  
ANSI/NFPA 70 - latest edition and all local codes and 
ordinances. 

 
The National Electrical Code requires a 4-wire power supply 
connection for homes built after 1996, dryer circuits involved 
in remodeling after 1996, and all mobile home installations. 

 
A copy of the above code standards can be obtained from: 
National Fire Protection Association, One Batterymarch Park, 
Quincy, MA 02269.

 

To supply the required 3 or 4-wire, single phase, 120/240 V, 
60 Hz, AC only electrical supply (or 3 or 4-wire, 120/208 V 
electrical supply, if specified on the serial/rating plate) on a 
separate 30 A circuit, fused on both sides of the line. Connect 
to an individual branch circuit. Do not have a fuse in the 
neutral or grounding circuit.

 

Do not use an extension cord.

 

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that  
the ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of 

electrical connection you will be using and follow the instructions 
provided for it here.

 

This dryer is manufactured ready to install with a 3-wire 
electrical supply connection. The neutral ground conductor  
is permanently connected to the neutral conductor (white 
wire) within the dryer. If the dryer is installed with a 4-wire 
electrical supply connection, the neutral ground conductor 
must be removed from the external ground connector (green 
screw), and secured under the neutral terminal (center or 
white wire) of the terminal block. When the neutral ground 
conductor is secured under the neutral terminal (center or 
white wire) of the terminal block, the dryer cabinet is isolated 
from the neutral conductor.

 

If local codes do not permit the connection of a neutral  
ground wire to the neutral wire, see “Optional 3-wire 
connection” section.

 

A 4-wire power supply connection must be used when the 
appliance is installed in a location where grounding through  
the neutral conductor is prohibited. Grounding through the 
neutral is prohibited for (1) new branch-circuit installations,  
(2) mobile homes, (3) recreational vehicles, and (4) areas  
where local codes prohibit grounding through the neutral 
conductors.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with  

clothes dryers. The kit should contain:

 

A UL listed 30 A power supply cord, rated 120/240 V 
minimum, with a temperature rating of 140°F (60°C) 
minimum. The cord should be type SRD or SRDT, and  
be at least 4 ft. (1.22 m) long. The wires that connect to 
the dryer must end in ring terminals or spade terminals  
with upturned ends.

 

A UL listed strain relief.

If your outlet looks like this:

Then choose a 4-wire power supply cord with 

ring or spade terminals and UL listed strain 
relief. The 4-wire power supply cord, at least  
4 ft. (1.22 m) long, must have 4 10-gauge solid 
copper wires and match a 4-wire receptacle of 
NEMA Type 14-30 R. The ground wire (ground 
conductor) may be either green or bare. The 
neutral conductor must be identified by a 
white cover.

4-wire 

receptacle 

(14-30R)

If your outlet looks like this:

Then choose a 3-wire power supply cord with 

ring or spade terminals and UL listed strain 
relief. The 3-wire power supply cord, at least  
4 ft. (1.22 m) long, must have 3 10-gauge solid 
copper wires and match a 3-wire receptacle of 
NEMA Type 10-30 R. 

3-wire 

receptacle 

(10-30R)

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) 

and be:

 

Flexible armored cable or nonmetallic sheathed copper cable 
(with ground wire), covered with flexible metallic conduit. All 
current-carrying wires must be insulated.

 

10-gauge solid copper wire (do not use aluminum) at  
least 5 ft. (1.52 m) long.

Содержание MGD7230HC0

Страница 1: ...nt de l alimentation en gaz 36 Sp cifications de l alimentation du br leur 36 Canalisation de gaz de la s cheuse 36 INSTALLATION DES PIEDS DE NIVELLEMENT 36 EFFECTUER LE RACCORDEMENT LECTRIQUE U SEULE...

Страница 2: ...essages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DAN...

Страница 3: ...d repairs must be performed by a qualified or licensed contractor plumber or gas fitter qualified or licensed by the State of Massachusetts Acceptable Shut off Devices Gas Cocks and Ball Valves instal...

Страница 4: ...ts needed steam models Y connector Short inlet hose Rubber washer 4 Inlet hose If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should cont...

Страница 5: ...s of dryer to reduce noise transfer If a closet door or louvered door is installed top and bottom air openings in door are required Check code requirements Some codes limit or do not permit installati...

Страница 6: ...the dryer cabinet is isolated from the neutral conductor If local codes do not permit the connection of a neutral ground wire to the neutral wire see Optional 3 wire connection section A 4 wire power...

Страница 7: ...d in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or servic...

Страница 8: ...aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing Lengths over 20 ft 6 1 m should use l...

Страница 9: ...ng information please reference the Quick Reference Guide MAKE ELECTRICAL CONNECTION U S A ONLY ELECTRICAL CONNECTION Power Supply Cord WARNING Fire Hazard Use a new UL listed 30 amp power supply cord...

Страница 10: ...upply cord is inside the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Do not further tighten strain relief screws at this point If you...

Страница 11: ...al block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 3 wire Power Supply Cord Conn...

Страница 12: ...ion of the strain relief C through the hole below the terminal block opening B Reaching inside the terminal block opening screw the removable conduit connector A onto the strain relief threads 2 Attac...

Страница 13: ...ce hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tighten screws Finally reinsert tab of terminal block cover in...

Страница 14: ...ing method is acceptable before connecting 1 Prepare to connect neutral ground wire and neutral wire B A E Remove center terminal block screw B Remove neutral ground wire E from external ground conduc...

Страница 15: ...t compound on threads of all non flared male fittings If flexible metal tubing is used be sure there are no kinks NOTE For propane gas connections you must use pipe joint compound resistant to action...

Страница 16: ...ce Do not install in enclosed walls ceilings or floors The total length should not exceed 73 4 ft 2 4 m The length of flexible metal vent used must be included in the overall vent system design as sho...

Страница 17: ...ute that will provide straightest and most direct path outdoors Plan installation to use fewest number of elbows and turns When using elbows or making turns allow as much room as possible Bend vent gr...

Страница 18: ...replace rubber washer Turn cold water faucet off and remove washer inlet hose Remove old rubber washer from inlet hose and replace with new rubber washer 2 Attach short hose and Y connector Attach 2 f...

Страница 19: ...an result Turn on cold water faucet 6 Check that the water faucet is turned on Check for leaks 7 Check for leaks around Y connector faucets and hoses CONNECT VENT 1 Connect vent to exhaust outlet Usin...

Страница 20: ...st leveling legs 2 If dryer is not level prop up using a wood block Use wrench to adjust legs up or down and check again for levelness Locating Pins Locking Features Base trim on some models 3 Place t...

Страница 21: ...utton has been pushed firmly Dryer is plugged into an outlet and or electrical supply is connected Household fuse is intact and tight or circuit breaker has not tripped Dryer door is closed This dryer...

Страница 22: ...panel of dryer Set the hinge screws off to the side for reinstalling the door A B A B 3 Remove the dryer door by lifting upward and out to lift the door off the cabinet Lay the door on a flat covered...

Страница 23: ...2 Remove the 10 screws from the dryer door and setscrews off to the side 3 Remove the inner door by using a plastic putty knife to separate the sides and bottom of the dryer door and trim There are 2...

Страница 24: ...strike plug 6 Remove the door hinges and set off to the side 7 Remove the 3 screws down the left and right sides of the door to remove the outer trim pieces 8 Lift door up and rotate trim pieces to t...

Страница 25: ...ce with the hinges lined up with the hinge holes 11 Install 6 hinge screws and the other 4 screws 12 Install hinge covers and plugs Hinge covers will go inside ways to then rotate 90 and snap into pla...

Страница 26: ...ryer A screen blocked by lint can increase drying time To clean Style 1 1 Pull the lint screen straight up and out Press tab down on front and open lint screen Roll lint off the screen with your finge...

Страница 27: ...See Installation Instructions The venting system attached to the dryer plays a big role in good air flow Blocked or crushed vents as well as improper venting installation will reduce air flow and drye...

Страница 28: ...se trim before moving dryer See Base trim WARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electr...

Страница 29: ...NOTES W11268643B 2020 All rights reserved Tous droits r serv s Todos los derechos reservados 03 20...

Отзывы: