LOCATION REQUIREMENTS

Explosion Hazard

Keep flammable materials and vapors, such as 
gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the 
floor for a garage installation.

Failure to do so can result in death, explosion,
or fire.

You will need:

 

A location allowing for proper exhaust installation.  
See “Venting Requirements.”

 

A separate 15 or 20 A circuit needed for gas dryers and  
30 A circuit needed for electric dryers.

 

If using power supply cord, a grounded electrical outlet  
located within 2 ft. (610 mm) of either side of dryer.  
See “Electrical Requirements.”

 

Floor must support dryer weight of 200 lbs. (90.7 kg).  
Also consider weight of companion appliance.

 

Level floor with maximum slope of 1" (25 mm) under entire 
dryer. If slope is greater than 1" (25 mm), clothes may not 
tumble properly and automatic sensor cycles may not 
operate correctly.

 

For garage installation, place dryer at least 18" (460 mm) 
above floor. 

 

Steam models only:

 Cold water faucets located within  

4 ft. (1.2 m) of the water fill valves, and water pressure of  
20-100 psi (137.9-689.6 kPa). You may use your washer’s 
water supply by purchasing the necessary parts noted in 
“Parts needed.”

IMPORTANT:

 Do not operate, install, or store dryer where  

it will be exposed to water, weather, or at temperatures below  
45°F (7°C). Lower temperatures may cause dryer not to  
shut off at end of automatic sensor cycles, resulting in longer  
drying times.

NOTE:

 No other fuel-burning appliance can be installed in the 

same closet as a dryer.

INSTALLATION CLEARANCES

For each arrangement, consider allowing more space for ease of 

installation and servicing, spacing for companion appliances and 
clearances for walls, doors, and floor moldings. Space must be 
large enough to allow door to fully open. Add spacing on all sides 
of dryer to reduce noise transfer. If a closet door or louvered door 
is installed, top and bottom air openings in door are required.

Check code requirements. Some codes limit, or do not permit, 

installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.

Spacing for recessed area or closet installation

The dimensions shown are for the recommended spacing 

allowed. 

 

Additional spacing should be considered for ease of 
installation and servicing.

 

Additional clearances might be required for wall, door,  
and floor moldings.

 

Additional spacing of 1" (25 mm) on all sides of the  
dryer is recommended to reduce noise transfer.

 

For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilations openings  
are acceptable.

 

Companion appliance spacing should also be considered.

*Recommended/Minimum spacing

Mobile home - Additional installation requirements:

This dryer is suitable for mobile home installations.

The installation must conform to the Manufactured Home 

Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile home construction and 
Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

All dryers:

 

Metal exhaust system hardware, available for purchase  
from your dealer. For further information, see “Assistance  
or Service” section in your “Quick Reference Guide.”

 

Special provisions must be made in mobile homes to  
introduce outside air into dryer. Openings (such as a  
nearby window) should be at least twice as large as  
dryer exhaust opening.

For gas dryers mobile home installations:

 

Mobile Home Installation Hold-down Kit is available to order. 
For further information, see “Assistance or Service” section 
in your “Quick Reference Guide.”

6"/0"*

(152 mm/0 mm)

14" max

(356 mm)

1"

(25 mm)

18"

(460 mm)

3"

(76 mm)

3"

(76 mm)

48 in.

 

2

(310 cm

2

)

(155 cm

2

)

1"/0"*

(25 mm/0 mm)

24 in.

2

Содержание MGD7230HC0

Страница 1: ...nt de l alimentation en gaz 36 Sp cifications de l alimentation du br leur 36 Canalisation de gaz de la s cheuse 36 INSTALLATION DES PIEDS DE NIVELLEMENT 36 EFFECTUER LE RACCORDEMENT LECTRIQUE U SEULE...

Страница 2: ...essages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DAN...

Страница 3: ...d repairs must be performed by a qualified or licensed contractor plumber or gas fitter qualified or licensed by the State of Massachusetts Acceptable Shut off Devices Gas Cocks and Ball Valves instal...

Страница 4: ...ts needed steam models Y connector Short inlet hose Rubber washer 4 Inlet hose If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should cont...

Страница 5: ...s of dryer to reduce noise transfer If a closet door or louvered door is installed top and bottom air openings in door are required Check code requirements Some codes limit or do not permit installati...

Страница 6: ...the dryer cabinet is isolated from the neutral conductor If local codes do not permit the connection of a neutral ground wire to the neutral wire see Optional 3 wire connection section A 4 wire power...

Страница 7: ...d in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or servic...

Страница 8: ...aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing Lengths over 20 ft 6 1 m should use l...

Страница 9: ...ng information please reference the Quick Reference Guide MAKE ELECTRICAL CONNECTION U S A ONLY ELECTRICAL CONNECTION Power Supply Cord WARNING Fire Hazard Use a new UL listed 30 amp power supply cord...

Страница 10: ...upply cord is inside the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Do not further tighten strain relief screws at this point If you...

Страница 11: ...al block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 3 wire Power Supply Cord Conn...

Страница 12: ...ion of the strain relief C through the hole below the terminal block opening B Reaching inside the terminal block opening screw the removable conduit connector A onto the strain relief threads 2 Attac...

Страница 13: ...ce hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tighten screws Finally reinsert tab of terminal block cover in...

Страница 14: ...ing method is acceptable before connecting 1 Prepare to connect neutral ground wire and neutral wire B A E Remove center terminal block screw B Remove neutral ground wire E from external ground conduc...

Страница 15: ...t compound on threads of all non flared male fittings If flexible metal tubing is used be sure there are no kinks NOTE For propane gas connections you must use pipe joint compound resistant to action...

Страница 16: ...ce Do not install in enclosed walls ceilings or floors The total length should not exceed 73 4 ft 2 4 m The length of flexible metal vent used must be included in the overall vent system design as sho...

Страница 17: ...ute that will provide straightest and most direct path outdoors Plan installation to use fewest number of elbows and turns When using elbows or making turns allow as much room as possible Bend vent gr...

Страница 18: ...replace rubber washer Turn cold water faucet off and remove washer inlet hose Remove old rubber washer from inlet hose and replace with new rubber washer 2 Attach short hose and Y connector Attach 2 f...

Страница 19: ...an result Turn on cold water faucet 6 Check that the water faucet is turned on Check for leaks 7 Check for leaks around Y connector faucets and hoses CONNECT VENT 1 Connect vent to exhaust outlet Usin...

Страница 20: ...st leveling legs 2 If dryer is not level prop up using a wood block Use wrench to adjust legs up or down and check again for levelness Locating Pins Locking Features Base trim on some models 3 Place t...

Страница 21: ...utton has been pushed firmly Dryer is plugged into an outlet and or electrical supply is connected Household fuse is intact and tight or circuit breaker has not tripped Dryer door is closed This dryer...

Страница 22: ...panel of dryer Set the hinge screws off to the side for reinstalling the door A B A B 3 Remove the dryer door by lifting upward and out to lift the door off the cabinet Lay the door on a flat covered...

Страница 23: ...2 Remove the 10 screws from the dryer door and setscrews off to the side 3 Remove the inner door by using a plastic putty knife to separate the sides and bottom of the dryer door and trim There are 2...

Страница 24: ...strike plug 6 Remove the door hinges and set off to the side 7 Remove the 3 screws down the left and right sides of the door to remove the outer trim pieces 8 Lift door up and rotate trim pieces to t...

Страница 25: ...ce with the hinges lined up with the hinge holes 11 Install 6 hinge screws and the other 4 screws 12 Install hinge covers and plugs Hinge covers will go inside ways to then rotate 90 and snap into pla...

Страница 26: ...ryer A screen blocked by lint can increase drying time To clean Style 1 1 Pull the lint screen straight up and out Press tab down on front and open lint screen Roll lint off the screen with your finge...

Страница 27: ...See Installation Instructions The venting system attached to the dryer plays a big role in good air flow Blocked or crushed vents as well as improper venting installation will reduce air flow and drye...

Страница 28: ...se trim before moving dryer See Base trim WARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electr...

Страница 29: ...NOTES W11268643B 2020 All rights reserved Tous droits r serv s Todos los derechos reservados 03 20...

Отзывы: