If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power
cord/pigtail (wire size
must conform
to rating of dryer), or the dryer can be hard wired directly to
the service breaker panel. In both cases, a strain relief
must be
installed where the wiring enters
the dryer.
NOTE: A CIRCUIT SERVICING EACH DRYER MUST BE PROVIDED.
If local codes permit, power to a gas dryer can be made by the use of a flexible U.L. listed power cord/
pigtail (wire size
must conform
to rating of dryer), or the dryer can be hard wired directly to the
service breaker panel. In
ALL
cases, a strain relief
must be
installed where the wiring enters the
dryer.
SINGLE-PHASE (1Ø) ELECTRICAL
CONNECTION LEADS
Black
+
Positive
White
-
Neutral
Green
Ground