Maytag MDG35 Скачать руководство пользователя страница 2

2

Maytag Co.

112204 - 6

Dryer Safety

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance.  Always read and obey all
safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”.

These words mean:

You can be killed or seriously injured if you don’t
immediately  follow instructions.

You can be killed or seriously injured if you don’t follow
instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can happen if the instructions are not followed.

It is recommended that the owner post, in a prominent location, instructions for the customer’s use in the event the customer
smells gas.  This information should be obtained from your gas supplier.

Post the following warning in a prominent location.

WARNING: For your safety the information in
this manual must be followed to minimize the
risk of fire or explosion or to prevent property
damage, personal injury or death.

– Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

– WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; Do not
use any phone in your building.

Clear the room, building or area of all
occupants.

Immediately call your gas supplier from a
neighbor’s phone.  Follow the gas
supplier’s instructions.

If you cannot reach your gas supplier,
call the fire department.

– Installation and service must be performed by

a qualified installer, service agency or the gas
supplier.

AVERTISSEMENT: Assurez-vous de bien suivre
les instructions données dans cette notice pour
réduire au minimum le risque d’incendie ou
d’explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.

– Ne pas entreposer ni utiliser d’essence

ni d’autres vapeurs ou liquides
inflammables à proximité de cet appareil
ou de tout autre appareil.

– QUE FAIRE SI VOUS SENTEZ UNE

ODEUR DE GAZ:

Ne pas tenter d’allumer d’appareils.

Ne touchez à aucun interrupteur; Ne pas
vous servir des téléphones se trouvant
dans le bâtiment.

Évacuez la pièce, le bâtiment ou la zone.

Appelez immédiatement votre fournisseur
de gaz depuis un voisin.  Suivez les
instructions du fournisseur.

Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.

– L’installation et l’entretien doivent être assurés

par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.

POUR VOTRE SÉCURITÉ

Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs
ou liquides inflammables à proximité de cet appareil ou de
tout autre appareil.

!

 DANGER

!

 WARNING

!

Содержание MDG35

Страница 1: ...MDG35 MDG52 MDG78 Installation Manual Part No 112204 6 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE...

Страница 2: ...Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas sup...

Страница 3: ...similarly textured rubber like materials Clean lint screen every third load to fourth Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint dust and d...

Страница 4: ...r Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING The dryer must never be operated with any of the back guards or service panels removed Personal injury or fi...

Страница 5: ...ER 14 28 DRYERS PER 53 TRUCK 36 VOLTAGE AVAILABLE 120 1 2w 60 Hz APPROXIMATE NET WEIGHT 462 lb 209 6 kg APPROXIMATE SHIPPING WEIGHT 492 lb 223 2 kg AIRFLOW 319 cfm 9 03 cmm HEAT INPUT 64 000 Btu hr 16...

Страница 6: ...INER 10 22 DRYERS PER 53 TRUCK 28 VOLTAGE AVAILABLE 120 1 2w 60 Hz APPROXIMATE NET WEIGHT 610 lb 276 69 kg APPROXIMATE SHIPPING WEIGHT 640 lb 290 30 kg AIRFLOW 600 cfm 17 00 cmm HEAT INPUT 110 000 Btu...

Страница 7: ...9 20 DRYERS PER 48 53 TRUCK 25 27 VOLTAGE AVAILABLE 120 1 2w 60 Hz APPROXIMATE NET WEIGHT 745 lb 337 93 kg APPROXIMATE SHIPPING WEIGHT 775 lb 351 53 kg AIRFLOW 600 cfm 17 00 cmm HEAT INPUT 130 000 Btu...

Страница 8: ...perature remains between 40 F 4 44 C and 130 F 54 44 C Excessive Weight Hazard Use two or more people and mechanical equipment to lift move and install dryer Failure to do so can result in back or oth...

Страница 9: ...n completely for the MDG35 is 33 inches 83 8 cm and the MDG52 and MDG78 are 40 inches 101 6 cm B A minimum overhead clearance of 6 inches 15 24 cm is required C Dryer should be positioned a minimum of...

Страница 10: ...h national installation regulations of the country of destination Outside Venting Protection To shelter the outside end of the horizontal ductwork from the weather a 90 elbow bent downward should be i...

Страница 11: ...cted circuit must be provided to each dryer It is necessary to have a power disconnect for each dryer These disconnects must be located within 30 feet 9 meters of the dryer The dryer must be connected...

Страница 12: ...t provided just in front of electrical box and insert 3 4 UL listed strain relief into the holes Single Phase 1 Wiring Connections Hookup The electrical input connections are made into the rear servic...

Страница 13: ...dryer does not recommend the use of flexible gas supply line hose Pipe joint compounds that resist the action of natural propane and butane gases must be used on all non flare fittings In the U S A An...

Страница 14: ...ow or inconsistent pressure which will result in erratic operation of the burner ignition system TYPICAL NATURAL GAS INSTALLATION Electric Shock Hazard Disconnect power before servicing Replace all pa...

Страница 15: ...l state and federal regulations or codes Installing the S A F E System The fire suppression system must be supplied with a minimum water pipe size of 1 2 inch 12 7 mm and be provided with 40 psi 20 ps...

Страница 16: ...ever a preoperational test should be performed before the dryer is publicly used It is possible that adjustments have changed in transit or due to marginal location installation conditions Turn on ele...

Страница 17: ...hnician service agency or gas supplier If service is required contact the Maytag distributor from whom the equipment was purchased If the distributor cannot be contacted or is unknown contact the Mayt...

Страница 18: ...NOTES ______________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________...