112204 - 6

Maytag Co.

15

Electric Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electric
shock.

!

 WARNING

11. Turn gas cock to “ON” position and check for leaks with

soap solution.

12. Reinstall the toe panel.

13. Reconnect the power.

Water Information (PN Models Only)

Before You Start

Check Local Codes and Permits

Call your local water company or the proper municipal
authority for information regarding local codes.

IMPORTANT: 

It is your responsibility to have all plumbing

connections made by a qualified professional to ensure
that the plumbing installation is adequate and conforms to
local, state, and federal regulations or codes.

Installing the S.A.F.E. System

The fire suppression system must be supplied with a minimum
water pipe size of 1/2-inch (12.7 mm) and be provided with 40
psi +/- 20 psi (2.75 bar +/- 1.37 bar) of pressure.

If the rear area of the dryer or the water supply is located in
an area where it will be exposed to cold/freezing tempera-
tures, provisions must be made to protect these water lines
from freezing.

Connect the hose to the S.A.F.E. system.  The dryer must be
connected to the cold water supply valve using a new flexible
supply line/coupling.  Do not use old hoses.

1. Disconnect power from the dryer.

2. Remove rear panel.

3. Remove the 3/4” NH hose adapter from the tumbler.

4. Connect the 3/4” 11.5 NH hose adapter to the 3/8” N.P.T.

water connection located at the upper rear of the dryer.

5. Screw coupling on by hand until seated on the supply

valve.

Содержание MDG35

Страница 1: ...MDG35 MDG52 MDG78 Installation Manual Part No 112204 6 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE...

Страница 2: ...Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas sup...

Страница 3: ...similarly textured rubber like materials Clean lint screen every third load to fourth Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint dust and d...

Страница 4: ...r Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING The dryer must never be operated with any of the back guards or service panels removed Personal injury or fi...

Страница 5: ...ER 14 28 DRYERS PER 53 TRUCK 36 VOLTAGE AVAILABLE 120 1 2w 60 Hz APPROXIMATE NET WEIGHT 462 lb 209 6 kg APPROXIMATE SHIPPING WEIGHT 492 lb 223 2 kg AIRFLOW 319 cfm 9 03 cmm HEAT INPUT 64 000 Btu hr 16...

Страница 6: ...INER 10 22 DRYERS PER 53 TRUCK 28 VOLTAGE AVAILABLE 120 1 2w 60 Hz APPROXIMATE NET WEIGHT 610 lb 276 69 kg APPROXIMATE SHIPPING WEIGHT 640 lb 290 30 kg AIRFLOW 600 cfm 17 00 cmm HEAT INPUT 110 000 Btu...

Страница 7: ...9 20 DRYERS PER 48 53 TRUCK 25 27 VOLTAGE AVAILABLE 120 1 2w 60 Hz APPROXIMATE NET WEIGHT 745 lb 337 93 kg APPROXIMATE SHIPPING WEIGHT 775 lb 351 53 kg AIRFLOW 600 cfm 17 00 cmm HEAT INPUT 130 000 Btu...

Страница 8: ...perature remains between 40 F 4 44 C and 130 F 54 44 C Excessive Weight Hazard Use two or more people and mechanical equipment to lift move and install dryer Failure to do so can result in back or oth...

Страница 9: ...n completely for the MDG35 is 33 inches 83 8 cm and the MDG52 and MDG78 are 40 inches 101 6 cm B A minimum overhead clearance of 6 inches 15 24 cm is required C Dryer should be positioned a minimum of...

Страница 10: ...h national installation regulations of the country of destination Outside Venting Protection To shelter the outside end of the horizontal ductwork from the weather a 90 elbow bent downward should be i...

Страница 11: ...cted circuit must be provided to each dryer It is necessary to have a power disconnect for each dryer These disconnects must be located within 30 feet 9 meters of the dryer The dryer must be connected...

Страница 12: ...t provided just in front of electrical box and insert 3 4 UL listed strain relief into the holes Single Phase 1 Wiring Connections Hookup The electrical input connections are made into the rear servic...

Страница 13: ...dryer does not recommend the use of flexible gas supply line hose Pipe joint compounds that resist the action of natural propane and butane gases must be used on all non flare fittings In the U S A An...

Страница 14: ...ow or inconsistent pressure which will result in erratic operation of the burner ignition system TYPICAL NATURAL GAS INSTALLATION Electric Shock Hazard Disconnect power before servicing Replace all pa...

Страница 15: ...l state and federal regulations or codes Installing the S A F E System The fire suppression system must be supplied with a minimum water pipe size of 1 2 inch 12 7 mm and be provided with 40 psi 20 ps...

Страница 16: ...ever a preoperational test should be performed before the dryer is publicly used It is possible that adjustments have changed in transit or due to marginal location installation conditions Turn on ele...

Страница 17: ...hnician service agency or gas supplier If service is required contact the Maytag distributor from whom the equipment was purchased If the distributor cannot be contacted or is unknown contact the Mayt...

Страница 18: ...NOTES ______________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________...

Отзывы: