2. Electrical Service Specifications
a. Gas ONLY
IMPORTANT:
Figures shown are for non-reversing models only. For reversing models contact the
factory.
IMPORTANT:
The dryer
must be
connected to the electric supply shown on the data label that is
affixed to the back side of the top front control/service door. In the case of 208 VAC
or 240 VAC, the supply voltage must match the electric service specifications of the
data label exactly.
IMPORTANT:
The wire size
must be
properly sized to handle the related current.
WARNING: 208 VAC and 240 VAC ARE
NOT
THE
SAME.
Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE:
The manufacturer reserves the right to make changes in specifications at any time without
notice or obligation.
MDG-75 (Gas)
IMPORTANT
: 208 VAC and 240 VAC
ARE NOT THE SAME
.
When ordering,
specify
exact voltage
.
NOTE
:
A. When fuses are used they
must be
dual element, time delay, current limiting, class RK1 or RK5
ONLY
.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
B. Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY
. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase (3Ø) dryers
must be
3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
Dual Element
Time Delay
CIRCUIT
BREAKER
120 (60 Hz)
1ø
2
13
*
20
20
208 (60 Hz)
1ø
2
8
*
12
15
208 (60 Hz)
3ø
3/4
5
*
8
15
240 (50/60 Hz)
1ø
2
7
*
12
15
380-400 (50 Hz)
3ø
3/4
3
*
5
15
416 (50 Hz)
3ø
3/4
3
*
5
15
460 (60 Hz)
3ø
3/4
3
*
5
15
* AWG Stranded Wire Type ...size wire as per National Electrical Code or local codes.