d. Verify that the motors heat and door indicator lights, on the back side of the microprocessor controller
(computer) board are lit. (Refer to the
illustration below
.)
e. Open the main door.
The dryer must stop and
ALL
output indicator lights on the back side of the microprocessor controller
(computer) board must go out. (Refer to the
illustration above
.)
f. Try to restart the dryer with the main door open.
g. The microprocessor controller (computer) board’s light emitting diode (L.E.D.) display must read “DOOR.”
h. Close the main door and restart the dryer.