22
THERMOSTAT CALL AVAILABLE SPEEDS
(FSd menu)
G
F01
F02
F03
F04
F05
F06
F07
F08
F09
Circulation Speed Table
Cooling Mode Speed Selection
To change the main blower speed in COOLING mode, follow
the following steps:
NOTE:
If Heat Pump system is configured in OdS menu (HP1
or HP2) COOLING thermostat calls will include “Y1”/Y2” + “O”
terminals energized.
1. Press menu button until LED displays “AC1“(for single
stage COOLING) or “AC2 “(for Two stage COOLING).
Press option button and the LED will display the
currently selected speed number as Fxx (xx: Blower
speed number from 1 to 9).
2. The control shall cycle through available fan speeds
every time the option button is pressed. All 9 speeds
are available for both Single and Two Stage cooling.
3. When the menu button is pressed, the current displayed
speed shall stop flashing. Press the menu button again
to select the option and the control shall immediately
apply that blower setting and return to the corresponding
main menu.
THERMOSTAT CALL
(OdS: Terminal)
AVAILABLE SPEEDS
(AC1 menu)
1AC: Y1
1HP: Y1 + O
F01
F02
F03
F04
F05
F06
F07
F08
F09
Single Stage Cooling Speed Table
THERMOSTAT CALL
(OdS: Terminal)
AVAILABLE SPEEDS
(AC2 menu)
2AC: Y1 + Y2
2HP: Y1 + Y2 + O
F01
F02
F03
F04
F05
F06
F07
F08
F09
Two Stage Cooling Speed Table
Gas Heating Mode Speed Selection
To change the main blower speed in GAS HEATING mode,
see the following steps:
1. Press menu button until LED displays “gAF. Press
option button and LED will display the currently selected
fan speed as Fxx (xx: Blower speed number).
2. The control shall cycle through available speed number
every time the option button is pressed.
3. When the menu button is pressed, the current displayed
speed shall stop flashing. Press the menu button again
to select the option and the control shall immediately
apply that blower setting and return to the corresponding
main menu.
NOTE:
Each furnace model contains different allowable gas
heating speeds. Allowable gas heating speeds will be visible
within gAF fan speed menu.
Heat Pump Heating Mode Speed Selection
To change the main blower speed in Heat Pump HEATING
mode, follow the following steps:
1. Press menu button until LED displays “HP1“ (for
single stage HP HEATING) or “HP2 “(for Two stage
HP HEATING). Press option button and the LED will
display the currently selected speed number as Fxx
(xx: Blower speed number from 1 to 9).
2. The control shall cycle through available fan speeds
every time the option button is pressed. All 9 speeds are
available for both Single and Two Stage HP HEATING.
3. When the menu button is pressed, the current displayed
speed shall be selected, and control shall apply the
newly selected speed in next HP HEATING call.