background image

4

3.

Loosen set screws on wired terminals labeled
REMOTE and insert wires into the openings. Tighten
set screws. (See following figure for switch connection)

4.

Connect wires at door switch.

Jumper Placement 
Description

Jumper in position 
for external power

BATTERY POWERED

NOTE:

 For battery powered, the 2 jumpers must be

positioned on the center and left pins. See jumper pin location
in photo above.

POWERED CONNECTION

NOTE: 

For external power connection, the 2 jumpers must

be positioned on the center and right pins. See jumper
location in photo above.

External Power 
Connections

Wired Door Switch 
Connections

Mounting Sensor/Door Magnet Installation

for DD01E and DD01F Kits

DD01E and DD01F must be mounted on the top door frame
as close to the door as possible in the horizontal position.

A DT01* must be installed in the PTAC unit for the DD01E
or DD01F to be operable.

Skip these steps if not installing.

1. Remove motion sensor from mounting plate by pulling

apart.

2. Mount the back plate on the door trim directly above

the door using the enclosed screws.  (Position so the
UP arrow is pointing up.) Mount the DD01E as low as
possible on the door frame to be as close to the moving
part of the door as possible without interfering with
the door opening or closing.  Choose a location for
mounting the back plate that will provide good coverage
of the PIR for motion into the room. Make sure that
the DD01E will not interfere with the normal opening
and closing of the door.

DO NOT SNAP MOTION SENSOR IN PLACE UNTIL AFTER

BINDING PROCESS.

See Binding Instructions, page 10.

DOOR

DOOR TRIM

DD01*

DD01E and DD01F Mounting

3. Install two (2) AA batteries (included) into the back of

the sensor. Terminals are marked “+” and “-” for
polarity.

 Do NOT put batteries into the device until

AFTER the magnet location is selected to test.

Содержание Amana DD01E

Страница 1: ...repair it is possible to place yourself in a position which is more hazardous than when the unit is in operation Remember it is your responsibility to install the product safely and to know it well en...

Страница 2: ...ower at the fuse box or circuit breaker 2 If the cabinet front is screwed to the chassis remove the 1 4 screw or screws See following figure Front Mounting Screw accessed through louvers 3 Remove cabi...

Страница 3: ...bing or other contents behind the wall are unknown 5B Discard flush mount base extension Place the mounting base plate against the wall in the desired location and mark placement of right mounting hol...

Страница 4: ...installed in the PTAC unit for the DD01E or DD01F to be operable Skip these steps if not installing 1 Remove motion sensor from mounting plate by pulling apart 2 Mount the back plate on the door trim...

Страница 5: ...screw driver push down on the terminal button to open the socket insert wire into socketandreleasetheterminalbutton Insertonewireinto each of the two 2 terminals See following image for wire location...

Страница 6: ...obtain 15 16 from back of sensor mounting plate to the center of the magnet If you can easily slide a business card between the magnet and the DD01E or DD01F sensor unit is properly placed vertically...

Страница 7: ...Screw location located on each side of sensor SIDE VIEW P O S I T I O N A P O S I T I O N B P O S I T I O N C MAGNET SLOTS MAGNET HOLDER TOP VIEW INSTALL THE MAGNET IN THE CORRECT SLOT 15 16th FROM B...

Страница 8: ...hen the door extends into the room beyond the door frame POSITION A Spacers Two 2 1 4 spacers are included in kit CONSTRUCTION STYLE 4 Place magnet in Position A in instances when the door frame exten...

Страница 9: ...not accomplished within one minute remove batteries and repeat Steps 1 2 Configuration Settings ThePTACcontrolwillautomaticallyself configuretoworkwiththewallthermostat DS01EKit ifinstalledandbound T...

Страница 10: ...ars Then press the up and down arrows to select the room suffix Example For the unit serving the main living area in room 224 press the HEAT key until appears then press the up and down arrow keys to...

Страница 11: ...lace 6 Provided optional security screw may be used in the lower center of the thermostat OPTIONAL SECURITY SCREW 7 Snap motion sensor onto motion sensor mounting plate 8 Provided optional security sc...

Страница 12: ...00 99 00 99 C5 Room I D Digit 3 4 00 99 00 99 C6 Wired or Wireless Occupancy 0 Off 1 On 18 18 Hour Automatic Entry C8 Temp Limiting Cool 60 72 60 72 C9 Temp Limiting Heat 68 90 80 68 90 80 Cd English...

Страница 13: ...back temperature press the HEAT key until feature code comes up To scroll to a previously viewed feature codes press the COOL key Once you have scrolled to the feature press either the up or down arr...

Страница 14: ...10 To exit configuration mode Press the OFF key NOTE Configuration feature mode will also automatically exit if no keys are pressed for a period of two 2 minutes The changes made in configuration mode...

Страница 15: ...between the equipment and all persons This equipment is authorized for use under the United States Federal Communication Commission Rules and Regulations Code of Federal Regulations Chapter 47 part 1...

Страница 16: ...to Goodman Company L P Houston TX All rights reserved Goodman Company L P 5151 San Felipe Suite 500 Houston TX 77056 www amana ptac com 2009 2011 2013 2018 Goodman Company L P Due to our policy of co...

Отзывы: