background image

4

www.amana-hac.com

SS-AMVC80/ACVC80

SS-AMVC80/ACVC80

www.amana-hac.com

5

Specifications

ACVC80

0603B*A

ACVC80

0803B*A

ACVC80

0805C*A

ACVC80

1005C*A

Heating Capacity

High Fire Input (BTU/h)¹

60,000

80,000

80,000

100,000

High Fire Output (BTU/h)¹ 
     Natural Gas

48,000

64,000

64,000

80,000

     LP Gas

48,000

64,000

64,000

80,000

Low Fire Input (BTU/h)¹

42,000

56,000

56,000

70,000

Low Fire Output (BTU/h)¹ 
     Natural Gas

33,600

44,800

44,800

56,000

     LP Gas

33,600

44,800

44,800

56,000

AFUE²

80

80

80

80

Available AC @ 0.5” ESP

1.5 - 3.0

1.5 - 3.0

2.0 - 5.0

2.0 - 5.0

Temperature Rise Range (° F)

25-55 / 40-70

30-60 / 30-60

25-55 / 30-60

20-50 / 25-55

Circulator Blower

Size  (D x W)

10” x 8”

10” x 8”

10” x 10”

10” x 10”

Horsepower - RPM

1/2 

1/2

3/4

3/4

Speed

Variable ECM

Variable ECM

Variable ECM

Variable ECM

Vent Diameter²

4”

4”

4”

4”

No. of Burners

3

4

4

5

Electrical Data

Min. Circuit Ampacity³

7.75

7.75

10.6

10.6

Max. Overcurrent Device (amps)⁴

15

15

15

15

Ship Weight (lbs)

105

109

125

129

¹

 

Nat

ural Gas BTU/h; for altitudes above from 0’ to 4,500’ above sea level, reduce input rating 4% for each 1,000’ above 4,500’ altitude. Low-fire rate is 70% of high-

fire rate.

²  DOE AFUE based upon Isolated Combustion System (ICS)
³  Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. 

 

Extensive wire runs will require larger wire sizes.

⁴ 

Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit 

 

breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

• 

All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.

• 

Gas Service Connection ½” FPT

• 

Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

Содержание Amana ACVC80

Страница 1: ...two speed induced draft blower California Low NOx emissions compliant models available For installation in California s South Coast Air Quality Management District SCAQMD only This furnace does not me...

Страница 2: ...low Horizontal N Natural Gas C Downflow Horizontal X Low NOx Motor Cabinet Width V Variable Speed ECM ComfortBridge A 14 C 21 E Multi Speed ECM S Single Speed B 17 D 24 Gas Valve Maximum CFM M Modulat...

Страница 3: ...ariable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Vent Diameter 4 4 4 4 4 4 4 No of Burners 3 3 4 4 4 4 5 Electrical Data Min Circuit Ampacity 7 75 10 6 7 75 7 75 10 6 10 6...

Страница 4: ...Data Min Circuit Ampacity 7 75 7 75 10 6 10 6 Max Overcurrent Device amps 15 15 15 15 Ship Weight lbs 105 109 125 129 Natural Gas BTU h for altitudes above from 0 to 4 500 above sea level reduce input...

Страница 5: ...enclosure where accessibility clearances are greater Refer to the appropriate USA and Canadian codes In the USA the National Fuel Gas Code NFPA 54 ANSI Z223 1 In Canada the Canada National Standard o...

Страница 6: ...B 1 0 3 6 1 1 Approved for line contact in the horizontal position 24 clearance for serviceability recommended Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined i...

Страница 7: ...ling Speed 1 8 w c ESP AMVC800805C A AMVC800805D A AMVC801005C A Cooling Speed 1 8 w c ESP Tons High Stage Low Stage CFM Tons High Stage Low Stage CFM 2 800 560 2 800 560 3 1 200 840 3 1 200 840 4 1 6...

Страница 8: ...del AMVC800604B AMVC800603B AMVC800803B AMVC800805C AMVC800804C AMVC800805D AMVC801005C Filter Size in 1 16 x 25 Side or Bottom 1 16 x 25 Side or Bottom 2 16 x 25 Side or 1 20 x 25 Bottom Note Other s...

Страница 9: ...UT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 8...

Страница 10: ...ATOR BLOWER R GND JUNCTION BOX SWITCH TEMP NEUTRAL LINE BK 4 POLARIZED AND HI FS 2 PLUG CONNECTION DISCONNECT BR BL INTEGRATED CONTROL PROT DEVICE HIGH FIRE PRESSURE SWITCH W INTERNAL TO NO EQUIPMENT...

Отзывы: