background image

6

www.amana-hac.com

SS-AMVC80/ACVC80

SS-AMVC80/ACVC80

www.amana-hac.com

7

ACVC80 Dimensions

A
B

High-Voltage

Electrical

Low-Voltage

Electrical

Gas Inlet

11

⅜”

18

⅜”

19

⅝”

33

⅜”

28

Minimum Clearances to Combustible Materials

Sides

Rear

Front ¹

Vent ²

Top

SW

B

1

0

3

6

1

1

Approved for line contact in the horizontal position.
¹  24” clearance for serviceability recommended.
²  Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the 

 

Installation Manual for additional venting requirements.

 Model

Dimensions

Heights

W

D

H

A

B

ACVC800603B**

17½”

28”

33⅜"

17½”

16”

ACVC800803B**

17½”

28”

33⅜"

17½”

16”

ACVC800805C**

21”

28”

33⅜"

21”

19½”

ACVC801005C**

21”

28”

33⅜"

21”

19½”

Содержание Amana ACVC80

Страница 1: ...two speed induced draft blower California Low NOx emissions compliant models available For installation in California s South Coast Air Quality Management District SCAQMD only This furnace does not me...

Страница 2: ...low Horizontal N Natural Gas C Downflow Horizontal X Low NOx Motor Cabinet Width V Variable Speed ECM ComfortBridge A 14 C 21 E Multi Speed ECM S Single Speed B 17 D 24 Gas Valve Maximum CFM M Modulat...

Страница 3: ...ariable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Vent Diameter 4 4 4 4 4 4 4 No of Burners 3 3 4 4 4 4 5 Electrical Data Min Circuit Ampacity 7 75 10 6 7 75 7 75 10 6 10 6...

Страница 4: ...Data Min Circuit Ampacity 7 75 7 75 10 6 10 6 Max Overcurrent Device amps 15 15 15 15 Ship Weight lbs 105 109 125 129 Natural Gas BTU h for altitudes above from 0 to 4 500 above sea level reduce input...

Страница 5: ...enclosure where accessibility clearances are greater Refer to the appropriate USA and Canadian codes In the USA the National Fuel Gas Code NFPA 54 ANSI Z223 1 In Canada the Canada National Standard o...

Страница 6: ...B 1 0 3 6 1 1 Approved for line contact in the horizontal position 24 clearance for serviceability recommended Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined i...

Страница 7: ...ling Speed 1 8 w c ESP AMVC800805C A AMVC800805D A AMVC801005C A Cooling Speed 1 8 w c ESP Tons High Stage Low Stage CFM Tons High Stage Low Stage CFM 2 800 560 2 800 560 3 1 200 840 3 1 200 840 4 1 6...

Страница 8: ...del AMVC800604B AMVC800603B AMVC800803B AMVC800805C AMVC800804C AMVC800805D AMVC801005C Filter Size in 1 16 x 25 Side or Bottom 1 16 x 25 Side or Bottom 2 16 x 25 Side or 1 20 x 25 Bottom Note Other s...

Страница 9: ...UT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 8...

Страница 10: ...ATOR BLOWER R GND JUNCTION BOX SWITCH TEMP NEUTRAL LINE BK 4 POLARIZED AND HI FS 2 PLUG CONNECTION DISCONNECT BR BL INTEGRATED CONTROL PROT DEVICE HIGH FIRE PRESSURE SWITCH W INTERNAL TO NO EQUIPMENT...

Отзывы: