2

www.amana-hac.com

SS-AMVC80/ACVC80

SS-AMVC80/ACVC80

www.amana-hac.com

3

Nomenclature

A

M

V

C

80

040

4

C

*

**

1

2

3

4

5,6

7,8,9

10

11

12

13,14

Brand

Engineering

A - Amana® Brand

Major /Minor Revisions

*  Not used for inventory control.

Configuration

NOx

M - Upflow/Horizontal

   N - Natural Gas

C - Downflow/Horizontal

   X - Low NOx

Motor

Cabinet Width

V - Variable Speed ECM / ComfortBridge™

A - 14"             C - 21"

E - Multi-Speed ECM 

S - Single Speed

B - 17½"          D - 24½"

Gas Valve

Maximum CFM

M - Modulating

S - Single Stage

   2 -   800 CFM

   4 - 1600 CFM

C - Two Stage 

H - Convertible Single Phase

   3 - 1200 CFM

   5 - 2000 CFM

AFUE

MBTU/h

80 - 80% AFUE

040 - 40,000 BTU/h

100 - 100,000 BTU/h

060 - 60,000 BTU/h

120 - 120,000 BTU/h

080 - 80,000 BTU/h

Содержание Amana ACVC80

Страница 1: ...two speed induced draft blower California Low NOx emissions compliant models available For installation in California s South Coast Air Quality Management District SCAQMD only This furnace does not me...

Страница 2: ...low Horizontal N Natural Gas C Downflow Horizontal X Low NOx Motor Cabinet Width V Variable Speed ECM ComfortBridge A 14 C 21 E Multi Speed ECM S Single Speed B 17 D 24 Gas Valve Maximum CFM M Modulat...

Страница 3: ...ariable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Vent Diameter 4 4 4 4 4 4 4 No of Burners 3 3 4 4 4 4 5 Electrical Data Min Circuit Ampacity 7 75 10 6 7 75 7 75 10 6 10 6...

Страница 4: ...Data Min Circuit Ampacity 7 75 7 75 10 6 10 6 Max Overcurrent Device amps 15 15 15 15 Ship Weight lbs 105 109 125 129 Natural Gas BTU h for altitudes above from 0 to 4 500 above sea level reduce input...

Страница 5: ...enclosure where accessibility clearances are greater Refer to the appropriate USA and Canadian codes In the USA the National Fuel Gas Code NFPA 54 ANSI Z223 1 In Canada the Canada National Standard o...

Страница 6: ...B 1 0 3 6 1 1 Approved for line contact in the horizontal position 24 clearance for serviceability recommended Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined i...

Страница 7: ...ling Speed 1 8 w c ESP AMVC800805C A AMVC800805D A AMVC801005C A Cooling Speed 1 8 w c ESP Tons High Stage Low Stage CFM Tons High Stage Low Stage CFM 2 800 560 2 800 560 3 1 200 840 3 1 200 840 4 1 6...

Страница 8: ...del AMVC800604B AMVC800603B AMVC800803B AMVC800805C AMVC800804C AMVC800805D AMVC801005C Filter Size in 1 16 x 25 Side or Bottom 1 16 x 25 Side or Bottom 2 16 x 25 Side or 1 20 x 25 Bottom Note Other s...

Страница 9: ...UT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 8...

Страница 10: ...ATOR BLOWER R GND JUNCTION BOX SWITCH TEMP NEUTRAL LINE BK 4 POLARIZED AND HI FS 2 PLUG CONNECTION DISCONNECT BR BL INTEGRATED CONTROL PROT DEVICE HIGH FIRE PRESSURE SWITCH W INTERNAL TO NO EQUIPMENT...