Operating instructions SG-RSV 206/X
170912 v3.1cd
1
6
5
4
3
2
Product overview
Connections
Function, installation and commissioning
Function
Connections: Terminals:
Supply voltage
1, 5
Output
6, 5
Sensor 1
2, 3
Sensor 2
4, 3
The control unit has two monitoring circuits, which operate one output circuit. The
electronics monitor the electrical resistance of the sensors, which have a defined
closed-circuit current.
The control unit is operated with a voltage of 12 or 24 V DC. If the supply voltage is
connected, the control unit is ready for operation.
SG-RSV 206/1
Control unit SG-RSV 206/1 has a non-inverted pnp output, which is set to LOW when
the sensors are not activated.
If a sensor is activated or if a cable break occurs on a sensor, the output switches to
HIGH.
SG-RSV 206/2
Control unit SG-RSV 206/2 has an inverted pnp output, which is set to HIGH when
the sensors are not activated.
If a sensor is activated or if a cable break occurs on a sensor, the output switches to
LOW.