8
Total reset
Press PROG button on the receiver (1) until the R1 LED lights on (2).
Keep the programming PROG button pressed down and make a bridge with the “MR”
reset jumper (3).
The receiver will emit 10 warning sound signals (3), and then more at a faster
frequency, indicating that the operation has been carried out (4).
To exit programming mode, wait for 20 seconds or press PROG button on the receiver.
Two beeps will be heard.
9
Batteries
Storage
· Store the lithium cells in a cool, dry and ventilated area far from fires and heating sources.
· It is recommended the use of a non-combustible structure and keep adequate clearance between
walls and batteries.
· The maximum temperature suggested for the storage is +30°C.
· Higher temperatures are allowed but cause an increase in the self discharge of the battery and
speed up the process of passivation.
· In any case, never go over 100°C, as the batteries can break and cause a leakage.
· Arrange adequate protections to avoid possible damages to the batteries.
· Keep the batteries in their original packages until they are used.
· Do not expose the batteries directly to the sun light.
· Do not put a higher number of cartons one on another (respect what indicated).
· If in the same place are storage batteries with a total capacity >50,000Ah, it is suggested to
install an alarm for smoke and gas.
Usage
· If the battery is integral, store and handle with care (it is suggested to handle the batteries in a
ventilated place, do not smoke, eat or drink during the assembly).
· Do not expose at temperature higher than 100°C (it is recommended <85ºC).
· Avoid short circuit, crush, and exposition to heat sources.
· Do not disassemble the batteries or the battery packs, do not throw them in the fire, do not
perforate them, do not overheat or wet them.
· Material to avoid: water, oxidizing agents, alkalis.
Before disposing of the equipment, remove the batteries and dispose of them at a
proper place of disposal.
UM_320XXXX_RB3SYSTEM_EN_MAYSER_Rev00 Página 21/24
Содержание RADIOBAND 3G
Страница 1: ...RADIOBAND 3G RB3 T868 RB3 R868 USER S MANUAL...
Страница 5: ...Receiver RB3 R868 UM_320XXXX_RB3SYSTEM_EN_MAYSER_Rev00 P gina 5 24...
Страница 6: ...Transmitter RB3 T868 UM_320XXXX_RB3SYSTEM_EN_MAYSER_Rev00 P gina 6 24...
Страница 8: ...UM_320XXXX_RB3SYSTEM_EN_MAYSER_Rev00 P gina 8 24...
Страница 20: ...7 Troubleshooting UM_320XXXX_RB3SYSTEM_EN_MAYSER_Rev00 P gina 20 24...
Страница 22: ...Technical data summary UM_320XXXX_RB3SYSTEM_EN_MAYSER_Rev00 P gina 22 24...