Mayr ROBA 059.500.2 Скачать руководство пользователя страница 6

Installation and Operational Instructions for

 

ROBA

®

-brake-checker AC Type 059.500.2 

(B.0595002.EN)

your reliable partner

27/06/2019 HH/GF/GC 

Page 6 of 8

Chr. Mayr GmbH + Co. KG
Eichenstraße 1, D-87665 Mauerstetten, Germany
Tel.: +49 8341 804-0, Fax: +49 8341 804-421

www.mayr.com

, E-Mail: 

[email protected]

66

MTTF

140 years at 60 °C
200 years at 40 °C

Duration of use

20 years

The basis of the MTTF calculation forms (if available) the 
information of the component manufacturer supplemented 
by the information from the Siemens standard SN 29500. 
The simplified Parts Count procedure ISO 13849-1 has been 
used for the calculation.

Interruption of the voltage at control terminal 1  Supply volt-
age +24 VDC: 
All outputs (signal, error, warning) are reset.
•  Signal (output) is set to 0 VDC (low)
•  Error (output) is set to 24 VDC (high)

Reliability Nominal Values

Reset

Fast switch-off

Intended Use

ROBA

®

-brake-checker products have been developed, 

manufactured and tested as electronic equipment in 

compliance with the DIN EN 50178 standard and in 

accordance with the EU Low Voltage Directive. During 

installation, operation and maintenance of the product, the 

requirements for the standard must be observed. ROBA

®

-

brake-checker products are for use in machines, systems 

and devices and must only be used in the situations for 

which they are ordered and confirmed. The products are 

designed for installation into electrical control cabinets and 

terminal boxes. Using them for any other purpose is not 

allowed.

Frequency Change (50/60 Hz)

After a frequency change in the input voltage, the switching-

on process (energisation) is not detected, or an error is 

indicated.

•  Switch on (energise) the brake again

•   After this “initialisation switching“, the ROBA

®

-brake-

checker can be operated as normal.

Inching Mode

During inching mode (fast sequence of switching on and 

off), no reliable detection is possible. 

After the end of inching mode, restart the monitoring 

function:

•  De-energise the brake

•  Switch on (energise) the brake again

Repeated switch-on (energisation) before the brake is closed 

generates a fault when the maximum current is reached.

Start process

During each individual start process, all outputs (signal, 

error, warning) are reset. 

The outputs must be assessed for the plausibility of signal 

conditions, signal changes and their correct temporal 

sequence.

EMC-compatible Installation

•  Avoid antennae effects: Keep the supply 

cables as short as possible; do not form 
rings or loops with the cables!

•  Mount good earth connections onto the 

metal body of the brake.

•  Lay control cables (total length <30 m) 

separately from power cables or from 
strongly pulsating supply cables!

Undertake a fast switch-off such as in the 
wiring example with a DC-side contact K2.
(DC-side contact K2 between the output 
terminal of the rectifier (supply module) and 
the input terminal of the ROBA

®

-brake-

checker).

Time Delays

Functional Guidelines

Recovery Time

20 ms

Reset

>20 ms

Signal delay

approx. 40 ms

overexcitation

×

 t

2

 + 200 ms

66

Содержание ROBA 059.500.2

Страница 1: ...ectromagnetic fields Guidelines on the Machinery Directive 2006 42 EC The product is a component for installation into machines according to the Machinery Directive 2006 42 EC The product can fulfil t...

Страница 2: ...hort circuits and earth short circuits at the terminals Electronic devices cannot be guaranteed During the risk assessment required when designing the ma chine or system the dangers involved must be e...

Страница 3: ...rectifiers or to fast acting rectifiers based on half wave or bridge rectification which are supplied with alternating voltage 50 60 Hz The module is switched between the rectifier and the brake and...

Страница 4: ...rop on feed lines to the brake Technical Data Size 20 Supply voltage control terminal SELV PELV ripple content 5 UI VDC 24 7 30 Coil current max Imax A 3 5 at 45 C IRMS A 3 5 at 60 C IRMS A 3 at 70 C...

Страница 5: ...ltage 0 VDC 6 Output voltage 7 Output voltage 8 Input voltage 104 432 VDC Wiring Example Outputs Signal 3 0 VDC low Brake is not energised movement of the armature disk for closing the brake 24 VDC hi...

Страница 6: ...lectrical control cabinets and terminal boxes Using them for any other purpose is not allowed Frequency Change 50 60 Hz After a frequency change in the input voltage the switching on process energisat...

Страница 7: ...595002 EN your reliable partner 27 06 2019 HH GF GC Page 7 of 8 Chr Mayr GmbH Co KG Eichenstra e 1 D 87665 Mauerstetten Germany Tel 49 8341 804 0 Fax 49 8341 804 421 www mayr com E Mail info mayr com...

Страница 8: ...clean the brake check the air gap Replace the brake if necessary Correct input voltage polarity Check input voltage and rotate if necessary Error continuous signal Brake release is not recognised Brak...

Отзывы: